Literature DB >> 8731205

Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis.

M Akay1, N Aslan.   

Abstract

A comparative stress analysis of a polymeric composite hip joint replacement was performed. A prototype short carbon-fiber reinforced PEEK (CF/PEEK) prosthesis was manufactured by injection molding. Finite element (FE) analysis was conducted on intact femurs and femurs fitted with the CF/ PEEK and the titanium prostheses under various loading conditions. FE models were validated by experimental strain gauge measurements by using synthetic femurs. There was a good agreement between the two methods except in the hoop strain of the femur in the calcar region because of the assumption of the isotropic material properties. The stem stresses were lower for the CF/PEEK prosthesis than for the titanium prosthesis. The maximum stress was in the spigot of the CF/PEEK prosthesis, but in the middle third of the stem of the titanium prosthesis. Stress generated in the cement was almost equal for both prostheses although more load was transferred, via cement, to the femur with the CF/ PEEK prosthesis because the load transfer took place over a larger area. An out-of-plane component of the joint load causes higher prosthesis and cement stresses.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8731205     DOI: 10.1002/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  12 in total

1.  An experimental and theoretical composite model of the human mandible.

Authors:  R De Santis; F Mollica; R Esposito; L Ambrosio; L Nicolais
Journal:  J Mater Sci Mater Med       Date:  2005-12       Impact factor: 3.896

2.  Performance of CF/PA12 composite femoral stems.

Authors:  Melissa Campbell; Martin N Bureau; L'Hocine Yahia
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

3.  The long-term mechanical integrity of non-reinforced PEEK-OPTIMA polymer for demanding spinal applications: experimental and finite-element analysis.

Authors:  Stephen J Ferguson; Judith M A Visser; Anne Polikeit
Journal:  Eur Spine J       Date:  2005-06-07       Impact factor: 3.134

4.  A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements.

Authors:  Habiba Bougherara; Rad Zdero; Suraj Shah; Milan Miric; Marcello Papini; Paul Zalzal; Emil H Schemitsch
Journal:  J Orthop Surg Res       Date:  2010-05-12       Impact factor: 2.359

5.  Thermal analysis studies of poly(etheretherketone)/hydroxyapatite biocomposite mixtures.

Authors:  B J Meenan; C McClorey; M Akay
Journal:  J Mater Sci Mater Med       Date:  2000-08       Impact factor: 3.896

Review 6.  PEEK biomaterials in trauma, orthopedic, and spinal implants.

Authors:  Steven M Kurtz; John N Devine
Journal:  Biomaterials       Date:  2007-08-07       Impact factor: 12.479

7.  A preclinical numerical assessment of a polyetheretherketone femoral component in total knee arthroplasty during gait.

Authors:  Lennert de Ruiter; Dennis Janssen; Adam Briscoe; Nico Verdonschot
Journal:  J Exp Orthop       Date:  2017-02-01

8.  Optimization of a Functionally Graded Material Stem in the Femoral Component of a Cemented Hip Arthroplasty: Influence of Dimensionality of FGM.

Authors:  Abdellah Ait Moussa; Rohan Yadav
Journal:  J Med Eng       Date:  2017-06-21

9.  Comparison of various functionally graded femoral prostheses by finite element analysis.

Authors:  Azim Ataollahi Oshkour; Hossein Talebi; Seyed Farid Seyed Shirazi; Mehdi Bayat; Yat Huang Yau; Faris Tarlochan; Noor Azuan Abu Osman
Journal:  ScientificWorldJournal       Date:  2014-08-27

10.  The mechanical response of a polyetheretherketone femoral knee implant under a deep squatting loading condition.

Authors:  Lennert de Ruiter; Dennis Janssen; Adam Briscoe; Nico Verdonschot
Journal:  Proc Inst Mech Eng H       Date:  2017-11-04       Impact factor: 1.617

View more