Literature DB >> 8731143

Similarity in behavior of polytetrafluoroethylene (ePTFE) prostheses implanted into different interfaces.

J M Bellón1, J Buján, L A Contreras, A Hernando, F Jurado.   

Abstract

The biomaterial ePTFE is widely used in the clinical environment for vascular replacement or bypass, as well as in the repair of tissue defects, especially those involving the abdominal wall. The objective of this study was to evaluate the healing response to ePTFE prostheses implanted into a circulatory interface and a tissue interface, each in a different animal species. For vascular implants, the Sprague-Dawley rat (n = 60) was used, while the New Zealand white rabbit (n = 20) was used in the tissue replacement model. In the former, a vascular microprosthesis measuring 5 mm in length and 1 mm in internal diameter, having a porosity of 30 microns, was implanted into the common iliac artery. In the rabbit, a 7 x 5-cm fragment of ePTFE (Soft-Tissue Patch) was implanted into a defect in anterior abdominal wall that involved all the tissue layers. In this case, the prosthesis was left touching the intestinal loops. The implants were studied between 14 and 90 days of postimplantation by means of light microscopy, scanning electron microscopy, and immunohistochemistry. The latter involved the use of anti-rat (MAC-341) and anti-rabbit (RAM-11) macrophage-specific monoclonal antibodies. The behavior of the ePTFE in the different interfaces (vascular and abdominal wall) was similar with respect to the following aspects: the prosthesis presented a process of encapsulation which was more intense on the outer surface; colonization of the implant was limited to the outermost two thirds, with minimal invasion of the middle portion; colonization was absent on the edges of the prosthesis; collagenization of the interstice of the mesh occurred late; the foreign body reaction taking place on the outer surface was similar in both interfaces, with formation of a barrier consisting of macrophages and giant cells that did not penetrate the prosthesis; and, finally, in neither of the two models was vascular colonization of the PTFE prosthesis observed; rather, the angiogenic process was limited to the periprosthetic zones. The integration of the implant made of ePTFE is similar despite the differences in interfaces and the use of different animal species. The macrophage response does not determine the success or failure of the implant.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8731143     DOI: 10.1002/(SICI)1097-4636(199605)31:1<1::AID-JBM1>3.0.CO;2-S

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  5 in total

Review 1.  Biocompatibility screening in cardiovascular implants.

Authors:  M Sigler; T Paul; R G Grabitz
Journal:  Z Kardiol       Date:  2005-06

2.  Salvage repair of anastomotic dehiscence following colon surgery using an expanded polytetrafluoroethylene graft.

Authors:  M A Uzun; N Koksal; O F Ozkan; M Kayahan; G Gumrukcu
Journal:  Tech Coloproctol       Date:  2010-08-06       Impact factor: 3.781

3.  Analysis of the inflammatory response to titanium and PTFE implants in soft tissue by macrophage phenotype quantification.

Authors:  A Rosengren; L M Bjursten; N Danielsen
Journal:  J Mater Sci Mater Med       Date:  1998-07       Impact factor: 3.896

4.  A randomized, controlled, prospective trial to evaluate the haemostatic effect of Lyostypt versus Surgicel in arterial bypass anastomosis: "COBBANA" trial.

Authors:  Petra Baumann; Hardy Schumacher; Johannes Hüsing; Steffen Luntz; Hanns-Peter Knaebel
Journal:  Trials       Date:  2009-09-29       Impact factor: 2.279

5.  Histologic Assessment of Drug-Eluting Grafts Related to Implantation Site.

Authors:  Jean-Christophe Tille; Sarra de Valence; Delia Mandracchia; Benjamin Nottelet; Francesco Innocente; Robert Gurny; Michael Möller; Beat H Walpoth
Journal:  J Dev Biol       Date:  2016-02-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.