Literature DB >> 8728364

Rotational stability of noncemented total hip femoral components.

L A Whiteside1, D S McCarthy, S E White.   

Abstract

Achieving torsional fixation of the femoral component in total hip arthroplasty is an important factor in success of the implant, so design features that improve fixation are likely to improve clinical results. Four femoral stem designs that allow different levels of femoral neck resection and use different distal fixation techniques were mechanically tested in cadaveric femurs to determine resistance to torsional loads. Five specimens for each stem design were implanted according to the standard procedure, and each was axially and torsionally loaded in a servohydraulic testing machine. Rotational interface micromotion and interface slippage were measured at the bone-implant interface. Decreased micromotion and interface slippage were associated with a distal scratch fit and neck retaining design, and the combination of distal scratch fit and neck retention had the least micromotion and smallest standard deviation of the four designs.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8728364

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  5 in total

1.  Neck-preserving femoral stems.

Authors:  Karthig Rajakulendran; Richard E Field
Journal:  HSS J       Date:  2012-09-07

2.  Modular femoral stems for revision total hip arthroplasty.

Authors:  Camilo Restrepo; Magdalena Mashadi; Javad Parvizi; Matthew S Austin; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

3.  Biomechanical testing of rectangular humeral shaft prosthesis: higher torsional stability without increased fracture risk.

Authors:  Matthias P Flury; Werner Schmoelz; Ulrich Schreiber; Joerg Goldhahn
Journal:  Arch Orthop Trauma Surg       Date:  2010-09-21       Impact factor: 3.067

4.  Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis.

Authors:  R Michael Meneghini; Nadim J Hallab; Richard A Berger; Joshua J Jacobs; Wayne G Paprosky; Aaron G Rosenberg
Journal:  J Orthop Surg Res       Date:  2006-10-02       Impact factor: 2.359

5.  Influence of implant variations on survival of the Lubinus SP II stem: evaluation of 76,530 hips in the Swedish Arthroplasty Register, 2000-2018.

Authors:  Raed Itayem; Ola Rolfson; Maziar Mohaddes; Johan Kärrholm
Journal:  Acta Orthop       Date:  2022-01-03       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.