Literature DB >> 8724418

Physiologic motion phantom for MRI applications.

M Drangova1, B Bowman, N Pelc.   

Abstract

To address the need for a complex physiologic motion phantom for use in MR applications, such as the verification of techniques for measuring myocardial motion dynamics and motion insensitive pulse sequences, a computer-controlled motion phantom has been designed. The phantom, which consists of a deformable silicone gel annulus mounted on a translation stage, can undergo a range of bulk motions and deformations. Available motions include bulk rotation and translation, rotational shear, axial shear, and combinations of some or all of these motions. In this paper, the capability of the phantom to produce accurate constant and time-varying waveforms is demonstrated. In the current implementation, peak linear translation and rotation rates are 175 mm s-1 and 10 rad s-1, respectively. Cycle-to-cycle reproducibility is excellent, with variations of less than .003 radians over the period of hours while undergoing rotational shear. The phantom has been designed in a flexible fashion so that various test objects can be scanned while undergoing bulk translation and can be adapted to produce different deformations.

Entities:  

Mesh:

Year:  1996        PMID: 8724418     DOI: 10.1002/jmri.1880060315

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform.

Authors:  Zheng Chang; Jing Cai; Ziheng Wang; Fang-Fang Yin
Journal:  J Radiosurg SBRT       Date:  2011

2.  Using synthetic data generation to train a cardiac motion tag tracking neural network.

Authors:  Michael Loecher; Luigi E Perotti; Daniel B Ennis
Journal:  Med Image Anal       Date:  2021-09-10       Impact factor: 8.545

3.  SimPACE: generating simulated motion corrupted BOLD data with synthetic-navigated acquisition for the development and evaluation of SLOMOCO: a new, highly effective slicewise motion correction.

Authors:  Erik B Beall; Mark J Lowe
Journal:  Neuroimage       Date:  2014-06-24       Impact factor: 6.556

4.  Development and characterization of rodent cardiac phantoms: comparison with in vivo cardiac imaging.

Authors:  Steven Fortune; Maurits A Jansen; Tom Anderson; Gillian A Gray; Jürgen E Schneider; Peter R Hoskins; Ian Marshall
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

Review 5.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

  5 in total