Literature DB >> 8724416

Dynamic range extension of cine velocity measurements using motion-registered spatiotemporal phase unwrapping.

G Z Yang1, P Burger, P J Kilner, S P Karwatowski, D N Firmin.   

Abstract

A motion-registered spatiotemporal phase-unwrapping method for extending the dynamic range of cine magnetic resonance phase velocity measurements is presented. The interframe cardiac movement is estimated from the magnitude image derived from the velocity encoded raw data, which ensures that the phase signal is unwrapped in the temporal direction with reference to pixels belonging to the same anatomic flow region. An extra step of spatial phase correction is then used to further eliminate any residual errors. The combination of spatial and temporal information for phase unwrapping provides a robust way of extending the dynamic range of cine velocity data in the presence of large phase aliasing errors.

Entities:  

Mesh:

Year:  1996        PMID: 8724416     DOI: 10.1002/jmri.1880060313

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

2.  Improved SNR in phase contrast velocimetry with five-point balanced flow encoding.

Authors:  Kevin M Johnson; Michael Markl
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

3.  Flow and myocardial interaction: an imaging perspective.

Authors:  Guang-Zhong Yang; Robert Merrifield; Sharmeen Masood; Philip J Kilner
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2007-08-29       Impact factor: 6.237

4.  Quantitative Phase Microscopy: how to make phase data meaningful.

Authors:  Goldie Goldstein; Katherine Creath
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-12

5.  Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice area.

Authors:  Julio Garcia; Oscar R Marrufo; Alfredo O Rodriguez; Eric Larose; Philippe Pibarot; Lyes Kadem
Journal:  J Cardiovasc Magn Reson       Date:  2012-04-06       Impact factor: 5.364

6.  Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms.

Authors:  M F Salfity; J M Huntley; M J Graves; O Marklund; R Cusack; D A Beauregard
Journal:  J R Soc Interface       Date:  2006-06-22       Impact factor: 4.118

  6 in total