Literature DB >> 8711909

Stereoacuity and colour contrast.

F A Kingdom1, D R Simmons.   

Abstract

We have measured the contrast dependence of stereoacuity using both horizontally and vertically oriented, isoluminant (red-green) and isochromatic (yellow-black), 0.5 c/deg Gabor patches. For comparison, contrasts were computed in multiples of detection threshold, where detection threshold was defined as the contrast required for the stimulus to be simultaneously detectable in each eye. Disparity thresholds (1/stereoacuity) for vertical chromatic Gabors were higher than those for vertical luminance Gabors by a factor of between 4 and 9 depending on contrast, and declined less steeply with contrast. Disparity thresholds for horizontal chromatic Gabors were very high (130-210 min arc) compared with horizontal luminance Gabors (by a factor of between 9 and 17) and were only measurable at contrasts above 10 times simultaneous monocular detection threshold. These results support the view that chromatic stereoscopic processing is less precise than luminance stereoscopic processing, and that there is a special deficit in the processing of disparity with horizontally oriented chromatic stimuli. The implications of these results for the role of colour vision in stereopsis are discussed.

Entities:  

Mesh:

Year:  1996        PMID: 8711909     DOI: 10.1016/0042-6989(95)00186-7

Source DB:  PubMed          Journal:  Vision Res        ISSN: 0042-6989            Impact factor:   1.886


  5 in total

1.  Depth perception in patients with congenital color vision deficiency.

Authors:  Serdar Ozates; Mehmet Ali Sekeroglu; Cagri Ilhan; Sibel Doguizi; Pelin Yilmazbas
Journal:  Eye (Lond)       Date:  2018-12-05       Impact factor: 3.775

2.  Effect of chromatic contrast on stereoacuity measurement with computer-aided three-dimensional technology.

Authors:  Lingzhi Zhao; Huang Wu
Journal:  Ann Transl Med       Date:  2019-05

3.  Stereoacuity of Black-White and Red-Green Patterns in Individuals with and without Color Deficiency.

Authors:  Ying Sun; Huang Wu; Yinghong Qiu; Zhiqiang Yue
Journal:  J Ophthalmol       Date:  2018-08-01       Impact factor: 1.909

4.  A novel clinical dynamic stereopsis assessment based on autostereoscopic display system.

Authors:  Yiyao Wang; Jing Zhong; Mengyi Cheng; Jijing Li; Ke Ma; Xiaoqing Hu; Naiyang Li; Haowen Liang; Zhengyuan Zhu; Jianying Zhou; Jin Yuan
Journal:  Ann Transl Med       Date:  2022-06

5.  The difference of distance stereoacuity measured with different separating methods.

Authors:  Lingzhi Zhao; Yu Zhang; Huang Wu; Jun Xiao
Journal:  Ann Transl Med       Date:  2020-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.