Microleakage of new dentin bonding systems using human and bovine teeth.

G W Reeves1, J G Fitchie, J H Hembree, A D Puckett.   

Abstract

The objective of this study was twofold: to evaluate the microleakage behavior of three dentin bonding systems and to determine if bovine teeth are comparable substrates to human teeth when studying the microleakage of various materials. The materials evaluated were Scotchbond Multi-Purpose Adhesive, Prisma Universal Bond 3, and All-Bond 2. All three bonding systems were used in combination with Prisma APH hybrid composite for comparison of microleakage behavior. Sixty class 5 preparations were cut at the cementoenamel junction for groups containing 30 human and 30 bovine teeth. A 1 mm 45 degree bevel was placed at the enamel margin. Teeth were grouped according to the dentin bonding system used and then restored according to the manufacturer's directions. After restoration, the teeth from each group were stored in distilled water at 37 degrees C for 3 days. The teeth were then thermocycled between 4 degrees C and 58 degrees C for 100 cycles and returned to distilled water at 37 degrees C for an additional 4 days. The teeth were then sealed with nail polish up to 1 mm from the margins of the restoration and placed in 45Ca isotope for 2 hours. The teeth were then sectioned and placed on x-ray film to produce autoradiographs. Microleakage was evaluated for the enamel and dentin margins separately using the following scale: 0 = no leakage, 1 = penetration of isotope to less than 1/2 the distance to the axial wall, 2 = penetration of isotope greater than 1/2 of the distance to the axial wall but short of the axial wall, and 3 = penetration of isotope to the axial wall or beyond. The materials were compared to each other using the Mann-Whitney U and Kruskal-Wallis tests. The gingival margins were compared to the incisal margins for all materials. No statistically significant differences in microleakage were revealed between the incisal and gingival location for human substrates, but there was statistically significant greater gingival microleakage for bovine substrates. All-Bond 2 leaked significantly more than Scotchbond Multi-Purpose for human substrates at the incisal margin. All-Bond 2 had significantly more microleakage than Prisma Universal Bond 3 at both dentin and enamel margins for the bovine substrate. There were no statistically significant differences in microleakage among the bonding systems for the human substrate. No statistically significant differences between the microleakage behavior of human and bovine substrates were found. These results support the use of bovine teeth for in vitro microleakage studies.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8710704

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  11 in total

1.  Effect of light polymerization time, mode, and thermal and mechanical load cycling on microleakage in resin composite restorations.

Authors:  Giulliana Panfiglio Soares; Glaucia Maria Bovi Ambrosano; Debora Alves Nunes Leite Lima; Giselle Maria Marchi; Lourenço Correr-Sobrinho; José Roberto Lovadino; Flávio Henrique Baggio Aguiar
Journal:  Lasers Med Sci       Date:  2013-01-13       Impact factor: 3.161

2.  The effects of application time of a self-etching primer and debonding methods on bracket bond strength.

Authors:  Brandon C Parrish; Thomas R Katona; Serkis C Isikbay; Kelton T Stewart; Katherine S Kula
Journal:  Angle Orthod       Date:  2011-07-28       Impact factor: 2.079

3.  Endodontic drug delivery for root surface disinfection: a laboratory feasibility evaluation.

Authors:  Markus Zaruba; Dan-K Rechenberg; Thomas Thurnheer; Thomas Attin; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2015-09-01       Impact factor: 3.573

Review 4.  Water flow on erbium:yttrium-aluminum-garnet laser irradiation: effects on dental tissues.

Authors:  Vivian Colucci; Flávia Lucisano Botelho do Amaral; Jesus Djalma Pécora; Regina Guenka Palma-Dibb; Silmara Aparecida Milori Corona
Journal:  Lasers Med Sci       Date:  2008-04-19       Impact factor: 3.161

5.  Evaluation of bovine and human teeth exposed to thermocycling for microleakage under bonded metal brackets.

Authors:  Kerem Canbek; Mareike Karbach; Franziska Gottschalk; Christina Erbe; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2013-03-07       Impact factor: 1.938

6.  The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation.

Authors:  Mansoreh Mirzaie; Esmail Yasini; Hamid Kermanshah; Baharan Ranjbar Omidi
Journal:  Dent Res J (Isfahan)       Date:  2014-01

7.  Effects of applying antioxidants on bond strength of bleached bovine dentin.

Authors:  Hyo-Jin Whang; Dong-Hoon Shin
Journal:  Restor Dent Endod       Date:  2014-10-13

8.  Shear bond strength and fracture analysis of human vs. bovine teeth.

Authors:  Stefan Rüttermann; Anika Braun; Ralf Janda
Journal:  PLoS One       Date:  2013-03-18       Impact factor: 3.240

9.  Influence of human and bovine substrate on the microleakage of two adhesive systems.

Authors:  Karoline Guará Brusaca Almeida; Kristine Guará Brusaca Almeida Scheibe; Ana Emília Figuerêdo Oliveira; Cláudia Maria Coêlho Alves; José Ferreira Costa
Journal:  J Appl Oral Sci       Date:  2009 Mar-Apr       Impact factor: 2.698

Review 10.  Evaluation of Microleakage of RMGIC and Flowable Composite Immersed in Soft Drink and Fresh Fruit Juice: An in vitro Study.

Authors:  Prabha Devi C Maganur; A R Prabhakar; Sugandhan S; Srinivas Namineni
Journal:  Int J Clin Pediatr Dent       Date:  2010-09-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.