Literature DB >> 8708077

Effect of geometrical distortion correction in MR on image registration accuracy.

C R Maurer1, G B Aboutanos, B M Dawant, S Gadamsetty, R A Margolin, R J Maciunas, J M Fitzpatrick.   

Abstract

In this article we investigate the effect of geometrical distortion correction in MR images on the accuracy of the registration of X-ray CT and MR head images for both a fiducial marker (extrinsic point) method and a surface-matching technique. We use CT and T2-weighted MR image volumes acquired from seven patients who underwent craniotomies in a stereotactic neurosurgical clinical trial. Each patient had four external markers attached to transcutaneous posts screwed into the outer table of the skull. The MR images are corrected for static field inhomogeneity by using an image rectification technique and corrected for scale distortion (gradient magnitude uncertainty) by using an attached stereotactic frame as an object of known shape and size. We define target registration error (TRE) as the distance between corresponding marker positions after registration and transformation. The accuracy of the fiducial marker method is determined by using each combination of three markers to estimate the transformation and the remaining marker to calculate registration error. Surface-based registration is accomplished by fitting MR contours corresponding to the CSF-dura interface to CT contours derived from the inner surface of the skull. The mean point-based TRE using three noncollinear fiducials improved 34%-from 1.15 to 0.76 mm-after correcting for both static field inhomogeneity and scale distortion. The mean surface-based TRE improved 46%-from 2.20 to 1.19 mm. Correction of geometrical distortion in MR images can significantly improve the accuracy of point-based and surface-based registration of CT and MR head images. Distortion correction can be important in clinical situations such as stereotactic and functional neurosurgery where 1 to 2 mm accuracy is required.

Entities:  

Mesh:

Year:  1996        PMID: 8708077     DOI: 10.1097/00004728-199607000-00032

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  12 in total

1.  A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction.

Authors:  Fa-Hsuan Lin; Ying-Jui Chen; John W Belliveau; Lawrence L Wald
Journal:  Hum Brain Mapp       Date:  2003-06       Impact factor: 5.038

Review 2.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

3.  Technical note: the design of a stereotactic frame for direct MRI-anatomical correlation of the brachial plexus.

Authors:  Tom Van Hoof; Cyriel Mabilde; Luc Leybaert; Koenraad Verstraete; Katharina D'Herde
Journal:  Surg Radiol Anat       Date:  2005-10-25       Impact factor: 1.246

4.  Validation of a method for coregistering scalp recording locations with 3D structural MR images.

Authors:  Christopher Whalen; Edward L Maclin; Monica Fabiani; Gabriele Gratton
Journal:  Hum Brain Mapp       Date:  2008-11       Impact factor: 5.038

5.  An analysis of tracking error in image-guided neurosurgery.

Authors:  Ian J Gerard; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-01-04       Impact factor: 2.924

6.  Comparison of procedures for co-registering scalp-recording locations to anatomical magnetic resonance images.

Authors:  Antonio M Chiarelli; Edward L Maclin; Kathy A Low; Monica Fabiani; Gabriele Gratton
Journal:  J Biomed Opt       Date:  2015-01       Impact factor: 3.170

7.  Distortion correction in whole-body imaging of live mice using a 1-Tesla compact magnetic resonance imaging system.

Authors:  Shigeru Kiryu; Yusuke Inoue; Yoshitaka Masutani; Tomoyuki Haishi; Kohki Yoshikawa; Makoto Watanabe; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-06-30       Impact factor: 2.374

8.  A multiple-plane approach to measure the structural properties of functionally active regions in the human cortex.

Authors:  Xin Wang; Sarah N Garfinkel; Anthony P King; Mike Angstadt; Michael J Dennis; Hong Xie; Robert C Welsh; Marijo B Tamburrino; Israel Liberzon
Journal:  Neuroimage       Date:  2009-11-14       Impact factor: 6.556

9.  Integration of multidisciplinary technologies for real time target visualization and verification for radiotherapy.

Authors:  Wen-Chung Chang; Chin-Sheng Chen; Hung-Chi Tai; Chia-Yuan Liu; Yu-Jen Chen
Journal:  Onco Targets Ther       Date:  2014-06-23       Impact factor: 4.147

10.  An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

Authors:  C Yu; Z Petrovich; M L Apuzzo; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.