Literature DB >> 870644

Quantification of flow in a dynamic phantom using Rb81-Kr81m, and a Nal detector.

J D Idoine, B Leonard Holman, A G Jones, R J Schneider, K L Schroeder, R E Zimmerman.   

Abstract

Blood flow can be measured by monitoring the count rate of Krypton-81m after its parent, Rubidium-81 (a potassium analogue), has been deposited in the tissue. The steady-state Kr-81m count rate reflects both production by decay of Rb-81 and washout due to blood flow. Its use is theoretically superior to that of Xenon-133 for quantification of blood flow (cc/min per 100 gm) since: (1) multiple flow measurements can be obtained from a single arterial injection, (2) flow-dependent changes in the count rate of Kr-81m provide a steady-state measure of specific flow, and (3) errors due to uptake in fat are eliminated. The count rate of Kr-81m was measured as a function of flow in a dynamic phantom with a NaI crystal, suing both pure cyclotron-produced Rb-81 and commercially available samples with as much as 25% contamination from Rb-82m. The phantom was calibrated by measuring the flow-rate constants with Xe-133. No significant difference was found between the flow-rate constant measured with three pure samples. The ratio of the zero-flow Kr-81m count rate to the rate observed in the presence of flow showed excellent correlation with calibrated flow over a range of rate constant from 0 to 0.02 sec (-1). This study suggests that regional specific flow can be measured in vivo with currently available Nal detecting systems after the intra-arterial injection of Rb-81.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 870644

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow.

Authors:  H P Stoll; H Huwer; B Vollmar; J Bialy; M Schmitt; J W Peters; A Sommer; N Hellwig; K Bonaventura; M D Menger; H Schieffer
Journal:  J Nucl Cardiol       Date:  2000 May-Jun       Impact factor: 5.952

2.  Myocardial perfusion measured by dual-isotope acquisition of 81rubidium/81mkrypton: an experimental verification of the method.

Authors:  H P Stoll; W Bay; W Vogel; C Ozbek; A Hanser; H Schieffer; G Harbauer
Journal:  Basic Res Cardiol       Date:  1994 Jul-Aug       Impact factor: 17.165

3.  81mKr gas generator for lung ventilation study.

Authors:  T Koyama; T Koyama; Y Hirokawa; Y Yoshizawa; H Noma; T Horiguchi; Y Kiso; H Hasai; H Takemi
Journal:  Eur J Nucl Med       Date:  1980-12

4.  Single-photon emission tomography studies of rubidium-81 in the detection of ischaemic heart disease, using a stress-reinjection protocol.

Authors:  H Botsch; K Beringer; J Petersen; B Bauer; H Weidemann
Journal:  Eur J Nucl Med       Date:  1994-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.