Literature DB >> 10888397

Experimental validation of a new coronary guide wire labeled with rubidium 81/krypton 81m for continuous assessment of myocardial blood flow.

H P Stoll1, H Huwer, B Vollmar, J Bialy, M Schmitt, J W Peters, A Sommer, N Hellwig, K Bonaventura, M D Menger, H Schieffer.   

Abstract

BACKGROUND: The rubidium 81/krypton 81m method was suggested for assessment of myocardial blood flow (MBF) three decades ago. This study investigates the novel concept of using 81Rb-/81mKr-labeled coronary guide wires with wire-attached 81Rb activity and diffusable 81mKr gas for assessment of lesion-specific impairment of MBF by evaluation of the 81Rb/81mKr activity ratio. The feasibility of wire production is tested, and application of the method is investigated in the canine model. METHODS AND
RESULTS: Conventional coronary guide wires for angioplasty (0.014 in) were labeled with radioactive 81Rb/81mKr by ion bombardment of the wire tip. A total of 16 of the 18 wires labeled in series showed successful 81Rb fixation in combination with free 81mKr gas diffusability during quality control measurements. The suitability of the wires to assess MBF in combination with an external gamma ray detector was investigated in open-chested dogs. Electromagnetic measurement of coronary blood flow (CBF) was used as reference, providing a signal that is directly linked to volumetric MBF. The 81Rb/81mKr ratio tracked changes in CBF reliably in all 6 dogs. The found linear dependence of measured 81Rb/81mKr count rates on measured CBF supports the modeling assumptions made to apply the theoretic basis of the 81Rb/81mKr technique to 81Rb-labeled coronary guide wires.
CONCLUSION: 81Rb-/81mKr-labeled coronary guide wires provide a signal that indicates volumetric MBF directly. This unique capability may qualify the technique as a valuable tool for research purposes and as an attractive method for invasive cardiology at centers where the logistic arrangements for short-lived isotope supply are provided.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10888397     DOI: 10.1016/s1071-3581(00)80014-8

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  13 in total

1.  A 81Rb/81mKr generator made by ion implantation.

Authors:  G J Beyer; H L Ravn
Journal:  Int J Rad Appl Instrum A       Date:  1991

2.  Quantification of flow in a dynamic phantom using Rb81-Kr81m, and a Nal detector.

Authors:  J D Idoine; B Leonard Holman; A G Jones; R J Schneider; K L Schroeder; R E Zimmerman
Journal:  J Nucl Med       Date:  1977-06       Impact factor: 10.057

3.  Rubidium-81: a new myocardial scanning agent.

Authors:  N D Martin; B L Zaret; R L McGowan; H P Wells; M D Flamm
Journal:  Radiology       Date:  1974-06       Impact factor: 11.105

4.  Tissue perfusion measured using the ratio of 81Rb to 81mKr incorporated in the tissue.

Authors:  T Jones; C M Matthews
Journal:  Nature       Date:  1971-03-12       Impact factor: 49.962

5.  Doppler guide wire-derived coronary flow reserve distal to intermediate stenoses used in clinical decision making regarding interventional therapy.

Authors:  Y A Deychak; J Segal; J S Reiner; S Nachnani
Journal:  Am Heart J       Date:  1994-07       Impact factor: 4.749

6.  Pure 81 Rb for medical use obtained by electromagnetic isotope separation.

Authors:  A Hanser; B Feurer
Journal:  Int J Appl Radiat Isot       Date:  1981-11

7.  Myocardial oxygenation and transmural lactate metabolism during experimental acute coronary stenosis in pigs.

Authors:  P Gonschior; G M Gonschior; P F Conzen; J Hobbhahn; A E Goetz; K Peter; W Brendel
Journal:  Basic Res Cardiol       Date:  1992 Jan-Feb       Impact factor: 17.165

8.  [Electron microscopic comparison of the antithrombotic potential of 2 low osmolality iodine contrast media in percutaneous transluminal coronary angioplasty].

Authors:  T Lefèvre; A Bernard; M Bertrand; J M Lablanche; A Cequier; E Espuglas; J L Gayet; G Gosselin; R Bonan
Journal:  Arch Mal Coeur Vaiss       Date:  1994-02

9.  Non-invasive detection of reduced regional myocardial perfusion at rest in patients with unstable angina pectoris: increased regional 81mKr deposition following intravenous injection of 81Rb.

Authors:  R Zimmermann; H Tillmanns; B Bubeck; F J Neumann; A Ernst; H Bihl; A Hanser; W Kübler
Journal:  Nuklearmedizin       Date:  1991-08       Impact factor: 1.379

10.  Myocardial perfusion measured by dual-isotope acquisition of 81rubidium/81mkrypton: an experimental verification of the method.

Authors:  H P Stoll; W Bay; W Vogel; C Ozbek; A Hanser; H Schieffer; G Harbauer
Journal:  Basic Res Cardiol       Date:  1994 Jul-Aug       Impact factor: 17.165