Literature DB >> 8706204

Choice of anaesthetic regimen influences haemodynamic response to cemented arthroplasty.

C B Guest1, R J Byrick, C D Mazer, D F Wigglesworth, J B Mullen, J H Tong.   

Abstract

Haemodynamic changes during bilateral cemented arthroplasty (BCA) were compared in dogs anaesthetized with isoflurane/N2O (ISOF) or diazepam/fentanyl (100 microg x kg(-1))N2O(FENT). Eight animals were anaesthetized with each regimen. After establishing monitoring and recording baseline values, BCA was performed. Haemodynamic measurements included aortic blood pressure (ABP), pulmonary artery pressure (PAP), right and left atrial pressures, and cardiac output. These were recorded at 30, 60, 180 and 300 sec after BCA. Lungs were removed and examined postmortem using quantitative morphometry. Groups demonstrated similar increases in PAP (ISOF 15 +/- 2 to 32 +/- 7, FENT 19 +/- 4 to 38 +/- 13; P> 0.05 between groups, P< 0.05 vs baseline). The proportion of lung vasculature occluded by fat was not different between groups (ISOF 9.63 +/- 3.38%, FENT 8.85 +/- 2.20%). Stroke volume decreased similarly in both groups (P> 0,05 between groups, P< 0.05 vs baseline). However, ABP decreased within one minute of BCA in ISOF (111 +/- 17 to 55 +/- mmHg, P< 0.05 and two of eight dogs died. All FENT dogs survived and hypotension (118 +/- 20 to 102 +/- 24 mmHg) was transient and less severe (P< 0.05 vs ISOF). Increased heart rate (HR) was noted in FENT following BCA (73 +/- 8 to 108 +/- 25 beats x min(-1); P< 0.05). Baseline HR was higher in ISOF (P< 0.05) and no increase in HR was noted. Systemic vascular resistance decreased in ISOF (P< 0.05), but not FENT (P> 0.05 vs baseline, P< 0.05 vs ISOF). To assess the role of slower baseline HR in FENT (73 +/-8) versus ISOF (131 +/- 5), six FENT dogs were paced (130 beats x min(-1)) with epicardial leads and an AV sequential pulse generator to simulate the ISOF group's baseline HR. Haemodynamic stability was maintained in this group in spite of a more rapid baseline HR. The choice of anaesthetic regimen strongly influenced acute haemodynamic changes in response to BCA.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8706204     DOI: 10.1007/BF03011042

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  32 in total

Review 1.  Pulmonary thromboembolism: disease recognition and patient management.

Authors:  D J Dehring; J F Arens
Journal:  Anesthesiology       Date:  1990-07       Impact factor: 7.892

2.  High-volume, high-pressure pulsatile lavage during cemented arthroplasty.

Authors:  R J Byrick; R S Bell; J C Kay; J P Waddell; J B Mullen
Journal:  J Bone Joint Surg Am       Date:  1989-10       Impact factor: 5.284

3.  The effect of anaesthesia on changes in blood pressure and plasma cortisol levels induced by cementation with methylmethacrylate.

Authors:  N Svartling; A M Lehtinen; L Tarkkanen
Journal:  Acta Anaesthesiol Scand       Date:  1986-04       Impact factor: 2.105

4.  Elevation of intramedullary pressure when methylmethacrylate is inserted in total hip arthroplasty.

Authors:  R G Tronzo; T Kallos; M Q Wyche
Journal:  J Bone Joint Surg Am       Date:  1974-06       Impact factor: 5.284

5.  Segmental wall motion abnormalities in patients undergoing total hip replacement: correlations with intraoperative events.

Authors:  J W Propst; L C Siegel; I Schnittger; L Foppiano; S B Goodman; J G Brock-Utne
Journal:  Anesth Analg       Date:  1993-10       Impact factor: 5.108

6.  Effects of isoflurane on the baroreceptor reflex.

Authors:  J L Seagard; E O Elegbe; F A Hopp; Z J Bosnjak; J H von Colditz; J H Kalbfleisch; J P Kampine
Journal:  Anesthesiology       Date:  1983-12       Impact factor: 7.892

7.  Fentanyl and sufentanil anesthesia revisited: how much is enough?

Authors:  D M Philbin; C E Rosow; R C Schneider; G Koski; M N D'Ambra
Journal:  Anesthesiology       Date:  1990-07       Impact factor: 7.892

8.  The effect of the pericardium on right and left ventricular diastolic functions during isoflurane anesthesia.

Authors:  T Kawasaki; S Hoka; H Okamoto; S Takahashi
Journal:  Anesth Analg       Date:  1993-06       Impact factor: 5.108

9.  Blood pressure response and plasma fentanyl concentrations during high- and very high-dose fentanyl anesthesia for coronary artery surgery.

Authors:  J E Wynands; G E Townsend; P Wong; D G Whalley; C B Srikant; Y C Patel
Journal:  Anesth Analg       Date:  1983-07       Impact factor: 5.108

10.  Anesthetic depth defined using multiple noxious stimuli during isoflurane/oxygen anesthesia. II. Hemodynamic responses.

Authors:  A M Zbinden; S Petersen-Felix; D A Thomson
Journal:  Anesthesiology       Date:  1994-02       Impact factor: 7.892

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.