Segmental wall motion abnormalities in patients undergoing total hip replacement: correlations with intraoperative events.

J W Propst1, L C Siegel, I Schnittger, L Foppiano, S B Goodman, J G Brock-Utne.   

Abstract

We examined the effect of methylmethacrylate cement on venous embolization and cardiac function in 20 patients having total hip arthroplasty under general anesthesia. Segmental wall motion abnormalities and intracardiac targets (presumably emboli) were investigated by making videotaped recordings of the transgastric short axis and longitudinal 4-chamber views of the heart with transesophageal echocardiography at different points during surgery. The incidence of segmental wall motion abnormalities was the most frequent during insertion of cemented femoral prostheses (8 of 14 patients had wall motion abnormalities). This was significantly different from baseline measurements taken at the beginning of surgery (P < 0.05). In addition, there were also significantly more segmental wall motion abnormalities in patients having a cemented femoral component compared to those having an uncemented femoral prosthesis (P < 0.05). The incidence of wall motion abnormalities during acetabular and femoral reaming and during wound closure was not significantly different from baseline. Intracardiac targets (emboli) were seen in all 20 patients during surgery. The largest number of emboli occurred during reaming of the femur and during insertion of the femoral prosthesis. Significantly more emboli were seen with cemented components (P < 0.02). Most emboli were small (< 2 mm) and appeared similar to the microbubbles produced by agitating saline with a small amount of air. Six patients also had larger (> 5 mm) emboli that appeared to be solid material. One patent foramen ovale was detected (5% incidence). There were no adverse cardiac or neurologic events, and heart rate and arterial blood pressure remained within normal limits throughout surgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8214658     DOI: 10.1213/00000539-199310000-00015

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  Choice of anaesthetic regimen influences haemodynamic response to cemented arthroplasty.

Authors:  C B Guest; R J Byrick; C D Mazer; D F Wigglesworth; J B Mullen; J H Tong
Journal:  Can J Anaesth       Date:  1995-10       Impact factor: 5.063

2.  Right ventricular strain as predictor of pulmonary complications in patients with femur fracture.

Authors:  Hyun-Jin Kim; Hyung-Bok Park; Yongsung Suh; Hyun-Sun Kim; Yoon-Hyeong Cho; Tae-Young Choi; Eui-Seok Hwang; Deok-Kyu Cho
Journal:  Cardiovasc J Afr       Date:  2017-02-01       Impact factor: 1.167

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.