Literature DB >> 8691267

A robust edge detection method for gated radionuclide ventriculograms.

A D Nelson1, G J Muswick, R F Muzic, X Descamps.   

Abstract

UNLABELLED: We present a myocardial edge detection technique that was developed for fast, reproducible measurements of left ventricular ejection fraction in the clinical setting.
METHODS: This myocardial edge detection method compares three edge parameters--count amplitude and first and second count derivatives--in three consecutive locations along a radius to a predetermined template of these values. Each of the radii, defined at 10-degree intervals, has different template values that permit accurate edge detection even though adjacent structures, such as the left atrium and the right ventricle, alter edge parameters. The template for edge detection is based on either the average edge parameters determined from manually defined edges in 15 patients (automatic method) or an operator-defined edge in the first frame (semiautomatic method).
RESULTS: The edge detection methods were tested in 100 patients, and intraobserver variabilities as well as comparison with clinically obtained ejection fractions were calculated. The standard error of the estimate was less than 3.1% for all observer comparisons. In 15 patients with both high-count (400,000 counts per image) and low count (50,000 counts per image) studies, the mean absolute difference in ejection fraction was 2.6% for intraobserver comparisons.
CONCLUSION: A robust myocardial edge detection technique was developed that is applicable for routine clinical use.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8691267

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  3 in total

1.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

2.  Automatic quantification of right ventricular function with gated blood pool SPECT.

Authors:  Doumit Daou; Serge D Van Kriekinge; Carlos Coaguila; Rachida Lebtahi; Thierry Fourme; Olivier Sitbon; Florence Parent; Michel Slama; Dominique Le Guludec; Gerald Simonneau
Journal:  J Nucl Cardiol       Date:  2004 May-Jun       Impact factor: 5.952

3.  Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Authors:  Wassila Djaballah; Marc A Muller; Anne C Bertrand; Pierre Y Marie; Bernard Chalon; Karim Djaballah; Pierre Olivier; Andreï Codreanu; Gilles Karcher; Alain Bertrand
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.