Literature DB >> 8683044

Displaced intra-articular fractures of the distal radius: the effect of fracture displacement on contact stresses in a cadaver model.

M E Baratz1, J d Des Jardins, D D Anderson, J E Imbriglia.   

Abstract

Contact stresses in the wrist were measured after simulating displaced fractures of the lunate fossa in the distal radius of eight human cadaver arms. Osteotomies created displaced lunate fossa fractures of 0, 1, 2, and 3 mm. Contact stresses were measured with Fuji pressure-sensitive film after loads of 100 N were applied to the wrist through wrist flexor and extensor tendons. Mean contact stresses were significantly increased with step-offs of 1 mm or more. Maximum stresses and overloaded areas were significantly increased with step-offs of 2 mm or more. As the magnitude of the fracture displacement increased, there was a shift in the focus of the maximum stresses toward the fracture line. In this model, simulated displaced die-punch fractures created alterations in both the magnitude and location of contact stresses in the wrist joint.

Entities:  

Mesh:

Year:  1996        PMID: 8683044     DOI: 10.1016/s0363-5023(96)80098-0

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  15 in total

1.  [Not Available].

Authors:  K J Prommersberger; U Lanz
Journal:  Oper Orthop Traumatol       Date:  1998-06       Impact factor: 1.154

2.  Physical validation of a patient-specific contact finite element model of the ankle.

Authors:  Donald D Anderson; Jane K Goldsworthy; Wendy Li; M James Rudert; Yuki Tochigi; Thomas D Brown
Journal:  J Biomech       Date:  2007-04-12       Impact factor: 2.712

Review 3.  Management of complications of distal radius fractures.

Authors:  Alexandra L Mathews; Kevin C Chung
Journal:  Hand Clin       Date:  2015-02-28       Impact factor: 1.907

4.  Intraoperative Tilted Posteroanterior View for the Measurement of Distal Radius Articular Step-Off.

Authors:  Steven Beldner; Remy V Rabinovich; Daniel B Polatsch
Journal:  J Wrist Surg       Date:  2019-04-16

5.  Dorsal Lunate Facet Fracture Reduction Using a Bone Reduction Forceps.

Authors:  Jonathan Lans; Josefina Alvarez; Amir R Kachooei; Sezai Ozkan; Jesse B Jupiter
Journal:  J Wrist Surg       Date:  2018-10-03

6.  A three-dimensional finite element model of the radiocarpal joint: distal radius fracture step-off and stress transfer.

Authors:  Donald D Anderson; Balachandra R Deshpande; Thomas E Daniel; Mark E Baratz
Journal:  Iowa Orthop J       Date:  2005

7.  Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction.

Authors:  Re Anakwe; Lak Khan; Re Cook; Je McEachan
Journal:  J Orthop Surg Res       Date:  2010-08-05       Impact factor: 2.359

8.  The Effect of Displaced Dorsal Rim Fragment in a Distal Radius Fracture.

Authors:  Jae Kwang Kim; Yeo-Hon Yun; Dong Jun Kim
Journal:  J Wrist Surg       Date:  2016-01-06

9.  [Arthroscopically assisted osteosynthesis of intraarticular distal radius fractures].

Authors:  M Lutz; S Erhart; C Deml; T Klestil
Journal:  Oper Orthop Traumatol       Date:  2016-05-24       Impact factor: 1.154

10.  [Effects of ulnar styloid and sigmoid notch fractures on postoperative wrist function of patients with distal radius fracture].

Authors:  P Zhang; B Jia; X K Chen; Y Wang; W Huang; R J Lai; Z W Wang; J Xiong; T B Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-06-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.