Reducing symptoms during hemodialysis by continuously monitoring the hematocrit.

R R Steuer1, J K Leypoldt, A K Cheung, H O Senekjian, J M Conis.   

Abstract

Previous studies have demonstrated that patients on hemodialysis develop intradialytic symptoms when the blood volume decreases to a critical level. Using a continuous monitor (CRIT-LINE; In-Line Diagnostics, Riverdale, UT) to determine the instantaneous hematocrit and blood volume, we observed that certain intradialytic symptoms occurred at a patient-specific hematocrit. In the present study, we exploited this hematocrit threshold concept to decrease the occurrence of lightheadedness, cramping, and nausea, regardless of blood pressure changes. In the first phase of the study, hematocrit threshold was established in six hypotension-prone patients. Five patients entered into the second phase in which ultrafiltration rates were increased 25 percent above prescribed values at the beginning of the experimental sessions. Subsequently during the experimental sessions, ultrafiltration rates were manipulated to maintain the instantaneous hematocrit value 2 units below the established hematocrit threshold. Sessions without ultrafiltration rate adjustments based on hematocrit served as controls. There were no differences between experimental (n = 27) and control (n = 28) sessions with respect to treatment time (230 minutes v 229 minutes), fluid volume removed (3,351 mL v 3,383 mL), and maximum percentage change in systemic blood pressure (-26 percent v -24 percent). However, there were less symptoms during the experimental sessions (26 percent v 57 percent; P = 0.038). These data suggest that a twofold reduction in intradialytic symptoms can be achieved using continuous hematocrit monitoring without altering treatment times or volume removed in hypotension-prone patients.

Entities:  

Mesh:

Year:  1996        PMID: 8678063     DOI: 10.1016/s0272-6386(96)90163-8

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  15 in total

1.  Dynamic electrochemistry: a step in the right direction.

Authors:  Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

2.  Intra-Dialytic Hemoglobin Changes and Cardiovascular Events: A Cohort Study on Dialysis Outcomes and Practice Patterns in Japan.

Authors:  Takashi Hara; Miho Kimachi; Tatsuyoshi Ikenoue; Tadao Akizawa; Shunichi Fukuhara; Yosuke Yamamoto
Journal:  Am J Nephrol       Date:  2019-09-05       Impact factor: 3.754

3.  Potential effects of aggressive decongestion during the treatment of decompensated heart failure on renal function and survival.

Authors:  Jeffrey M Testani; Jennifer Chen; Brian D McCauley; Stephen E Kimmel; Richard P Shannon
Journal:  Circulation       Date:  2010-07-06       Impact factor: 29.690

4.  Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients.

Authors:  Christer Ahlstrom; Anders Johansson; Fredrik Uhlin; Toste Länne; Per Ask
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

5.  Intra-dialytic blood oxygen saturation (SO2): association with dialysis hypotension (the SOGLIA Study).

Authors:  E Mancini; C Perazzini; L Gesualdo; F Aucella; A Limido; F Scolari; S Savoldi; M Tramonti; L Corazza; M Atti; S Severi; P Bolasco; A Santoro
Journal:  J Nephrol       Date:  2016-08-29       Impact factor: 3.902

6.  Blood volume monitoring to adjust dry weight in hypertensive pediatric hemodialysis patients.

Authors:  Cengiz Candan; Lale Sever; Mahmut Civilibal; Salim Caliskan; Nil Arisoy
Journal:  Pediatr Nephrol       Date:  2008-09-10       Impact factor: 3.714

7.  Blood volume monitoring to achieve target weight in pediatric hemodialysis patients.

Authors:  Mini Michael; Eileen D Brewer; Stuart L Goldstein
Journal:  Pediatr Nephrol       Date:  2004-02-26       Impact factor: 3.714

8.  Randomized Crossover Trial of Blood Volume Monitoring-Guided Ultrafiltration Biofeedback to Reduce Intradialytic Hypotensive Episodes with Hemodialysis.

Authors:  Kelvin C W Leung; Robert R Quinn; Pietro Ravani; Henry Duff; Jennifer M MacRae
Journal:  Clin J Am Soc Nephrol       Date:  2017-10-10       Impact factor: 8.237

9.  Blood volume-monitored regulation of ultrafiltration in fluid-overloaded hemodialysis patients: study protocol for a randomized controlled trial.

Authors:  Manfred Hecking; Marlies Antlanger; Wolfgang Winnicki; Thomas Reiter; Johannes Werzowa; Michael Haidinger; Thomas Weichhart; Hans-Dietrich Polaschegg; Peter Josten; Isabella Exner; Katharina Lorenz-Turnheim; Manfred Eigner; Gernot Paul; Renate Klauser-Braun; Walter H Hörl; Gere Sunder-Plassmann; Marcus D Säemann
Journal:  Trials       Date:  2012-06-08       Impact factor: 2.279

10.  Real-time prediction of intradialytic relative blood volume: a proof-of-concept for integrated cloud computing infrastructure.

Authors:  Sheetal Chaudhuri; Hao Han; Caitlin Monaghan; John Larkin; Peter Waguespack; Brian Shulman; Zuwen Kuang; Srikanth Bellamkonda; Jane Brzozowski; Jeffrey Hymes; Mike Black; Peter Kotanko; Jeroen P Kooman; Franklin W Maddux; Len Usvyat
Journal:  BMC Nephrol       Date:  2021-08-09       Impact factor: 2.388

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.