Literature DB >> 8676269

Reduction of aerosols produced by ultrasonic scalers.

S K Harrel1, J B Barnes, F Rivera-Hidalgo.   

Abstract

There is concern with decreased air quality and potential aerosol contamination in the dental operatory. This problem has been addressed by the Centers for Disease Control and Prevention, which recommends that all sources of blood-contaminated splatter and aerosols be minimized. One of the major sources of potential aerosol contamination in the dental setting is the ultrasonic scaler. This study looks at the use of a high volume evacuator attachment for the ultrasonic scaler handpiece. Artificial teeth were mock-scaled for 1 minute with and without the evacuator attachment. The mock scaling was performed within a plastic enclosure that had a 1 cm grid laid out on 4 sides. Scaling was performed 10 times each by 2 operators. An erythrosin solution was used for the ultrasonic scaler coolant with a coolant volume of 17.5 ml/min. The number of squares containing a red erythrosin spot were counted and considered to represent aerosol contamination. The high volume evacuator attachment produced a 93% reduction in the number of contaminated squares (chi squared significant at P < 0.05). There was no increase in heat transfer to a tooth analogue when the high volume evacuator attachment was used with the ultrasonic scaler as compared to the scaler without the evacuator attachment. It is felt that the high volume evacuator attachment is capable of significantly reducing the amount of aerosol contamination produced within the test system without increased heat transfer to the tooth.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8676269     DOI: 10.1902/jop.1996.67.1.28

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  18 in total

1.  Application of ultrasound in periodontics: Part II.

Authors:  Vivek K Bains; Ranjana Mohan; Rhythm Bains
Journal:  J Indian Soc Periodontol       Date:  2008-09

2.  Measurement of particle concentrations in a dental office.

Authors:  Maria Sotiriou; Stephen F Ferguson; Mark Davey; Jack M Wolfson; Philip Demokritou; Joy Lawrence; Sonja N Sax; Petros Koutrakis
Journal:  Environ Monit Assess       Date:  2007-05-16       Impact factor: 3.307

3.  Efficacy versus health risks: An in vitro evaluation of power-driven scalers.

Authors:  Christian Graetz; Anna Plaumann; Jule Bielfeldt; Anica Tillner; Sonja Sälzer; Christof Edmund Dörfer
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

4.  Efficacy of High-volume Evacuator in Aerosol Reduction: Truth or Myth? A Clinical and Microbiological Study.

Authors:  Hitesh Desarda; Abhijit Gurav; Chandrakant Dharmadhikari; Abhijeet Shete; Subodh Gaikwad
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-09-17

5.  High total volatile organic compounds pollution in a hospital dental department.

Authors:  Ming-Hui Liu; Tao-Hsin Tung; Fen-Fang Chung; Li-Chuan Chuang; Gwo-Hwa Wan
Journal:  Environ Monit Assess       Date:  2017-10-18       Impact factor: 2.513

Review 6.  Modifications of emergency dental clinic protocols to combat COVID-19 transmission.

Authors:  Robert Hollinshead Long; Tyrous David Ward; Michael Edward Pruett; John Finklea Coleman; Marc Charles Plaisance
Journal:  Spec Care Dentist       Date:  2020-05-24

7.  Optimizing Safe Dental Practice During the COVID-19 Pandemic: Recommendations Based on a Guide Developed for Dental Practices in China.

Authors:  Li Li; Mianyan Zeng; Xiao Chen; Shuman Cai; Cuixia Xu; Wei Xia; Lijun Jiang; Xiaoyan Zou; Pei Chen; Mingdeng Rong
Journal:  Front Med (Lausanne)       Date:  2021-05-26

8.  A clinical investigation of dental evacuation systems in reducing aerosols.

Authors:  Montry S Suprono; John Won; Roberto Savignano; Zhe Zhong; Abu Ahmed; Gina Roque-Torres; Wu Zhang; Udochukwu Oyoyo; Paul Richardson; Joseph Caruso; Robert Handysides; Yiming Li
Journal:  J Am Dent Assoc       Date:  2021-06       Impact factor: 3.634

9.  Acute endodontic and dental trauma provision during the COVID-19 crisis.

Authors:  Khawer Ayub; Aws Alani
Journal:  Br Dent J       Date:  2020-08       Impact factor: 2.727

10.  The efficacy of an extraoral scavenging device on reduction of splatter contamination during dental aerosol generating procedures: an exploratory study.

Authors:  Shakeel Shahdad; Tulsi Patel; Annika Hindocha; Neil Cagney; Jens-Dominik Mueller; Noha Seoudi; Claire Morgan; Ahmed Din
Journal:  Br Dent J       Date:  2020-09-11       Impact factor: 2.727

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.