Literature DB >> 8662093

Quantitative exercise technetium-99m tetrofosmin myocardial tomography for the identification and localization of coronary artery disease.

P Sullo1, A Cuocolo, E Nicolai, S Cardei, A Nappi, F Squame, E M Covelli, L Pace, M Salvatore.   

Abstract

The aim of this study was to evaluate the accuracy of quantitative 1-day exercise-rest technetium-99m tetrofosmin tomography in the identification of patients with coronary artery disease (CAD) and in the detection of individual stenosed coronary vessels. Sixty-one patients with suspected CAD who underwent coronary angiography and 13 normal volunteers were studied. All patients were submitted to two i.v. injections of 99mTc-tetrofosmin, one at peak exercise (370 MBq) and the other (1110 MBq) at rest 3 h after exercise (images 15-30 min after injection for both studies). All patients with CAD (>/=50% luminal stenosis) (n=50) had an abnormal 99mTc-tetrofosmin tomogram. Only one patient without significant coronary narrowing showed abnormal findings. Overall sensitivity, specificity and diagnostic accuracy in the detection of individual stenosed vessels were 77%, 93% and 85%, respectively. Sensitivity and diagnostic accuracy in the identification of individuals stenosed coronary vessels were significantly higher (P<0.05) in patients with single-vessel disease (n=21) than in those with multivessel disease (n=29). Sensitivity, specificity and accuracy for detecting individual diseased vessels were similar in patients without previous myocardial infarction (n=26) and in those with previous myocardial infarction (n=35). In myocardial territories related to non-infarcted areas (n=128), sensitivity and specificity in the detection of stenosed vessels were 70% and 95%, respectively. In infarcted areas (n=55), sensitivity and specificity in the detection of stenosed vessels were 85% (P=NS vs non-infarcted areas) and 75% (P<0.05 vs non-infarcted areas), respectively. Finally, sensitivity was significantly lower (P<0.05) in vascular territories supplied by vessels with moderate stenosis (50%-75%) than in those supplied by vessels with severe stenosis (>75%). The results of this study demonstrate that quantitative 1-day exercise-rest 99mTc-tetrofosmin single-photon emission tomographic imaging is a suitable and accurate technique to identify patients with CAD and to detect individual stenosed coronary vessels.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8662093     DOI: 10.1007/bf00834526

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  37 in total

1.  Quantitative rotational tomography with 201Tl and 99mTc 2-methoxy-isobutyl-isonitrile. A direct comparison in normal individuals and patients with coronary artery disease.

Authors:  J K Kahn; I McGhie; M S Akers; M N Sills; T L Faber; P V Kulkarni; J T Willerson; J R Corbett
Journal:  Circulation       Date:  1989-06       Impact factor: 29.690

2.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

3.  Biokinetics of technetium-99m-tetrofosmin: myocardial perfusion imaging agent: implications for a one-day imaging protocol.

Authors:  D Jain; F J Wackers; J Mattera; M McMahon; A J Sinusas; B L Zaret
Journal:  J Nucl Med       Date:  1993-08       Impact factor: 10.057

4.  Diagnosis of coronary artery disease by controlled coronary vasodilation with adenosine and thallium-201 scintigraphy in patients unable to exercise.

Authors:  M S Verani; J J Mahmarian; J B Hixson; T M Boyce; R A Staudacher
Journal:  Circulation       Date:  1990-07       Impact factor: 29.690

5.  Differentiation of transiently ischemic from infarcted myocardium by serial imaging after a single dose of thallium-201.

Authors:  G M Pohost; L M Zir; R H Moore; K A McKusick; T E Guiney; G A Beller
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690

6.  Comparison between exercise and trans-oesophageal atrial pacing in patients with coronary artery disease: technetium-99m methoxy isobutyl isonitrile simultaneous evaluation of ventricular function and myocardial perfusion.

Authors:  A Cuocolo; M Santomauro; L Pace; L Celentano; A Nappi; E Nicolai; M Chiariello; M Salvatore
Journal:  Eur J Nucl Med       Date:  1992

7.  Prediction of cardiac events after uncomplicated myocardial infarction: a prospective study comparing predischarge exercise thallium-201 scintigraphy and coronary angiography.

Authors:  R S Gibson; D D Watson; G B Craddock; R S Crampton; D L Kaiser; M J Denny; G A Beller
Journal:  Circulation       Date:  1983-08       Impact factor: 29.690

8.  Adenosine technetium-99m-methoxy isobutyl isonitrile myocardial tomography in patients with coronary artery disease: comparison with exercise.

Authors:  A Cuocolo; A Soricelli; L Pace; E Nicolai; L Castelli; A Nappi; M Imbriaco; C Morisco; P J Ell; M Salvatore
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

9.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.

Authors:  E E DePasquale; A C Nody; E G DePuey; E V Garcia; G Pilcher; C Bredlau; G Roubin; A Gober; A Gruentzig; P D'Amato
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

10.  Comparison of thallium redistribution with rest "reinjection" imaging for the detection of viable myocardium.

Authors:  T P Rocco; V Dilsizian; K A McKusick; A J Fischman; C A Boucher; H W Strauss
Journal:  Am J Cardiol       Date:  1990-07-15       Impact factor: 2.778

View more
  5 in total

1.  Tetrofosmin imaging in the detection of myocardial viability in patients with previous myocardial infarction: comparison with sestamibi and Tl-201 scintigraphy.

Authors:  Wanda Acampa; Alberto Cuocolo; Mario Petretta; Andrea Bruno; Massimo Castellani; Andrea Finzi; Paolo Gerundini
Journal:  J Nucl Cardiol       Date:  2002 Jan-Feb       Impact factor: 5.952

2.  Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection.

Authors:  E Nicolai; A Cuocolo; W Acampa; A Varrone; L Pace; M Salvatore
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

3.  Dobutamine technetium-99m tetrofosmin SPECT imaging for the diagnosis of coronary artery disease in patients with limited exercise capacity.

Authors:  A Elhendy; F B Sozzi; R Valkema; R T van Domburg; J J Bax; J R Roelandt
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

4.  Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

Authors:  Assuero Giorgetti; Annette Kusch; Mirta Casagranda; Irene D'Aragona Tagliavia; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2009-12-15       Impact factor: 5.952

5.  Direct comparison of technetium 99m-sestamibi and technetium 99m-tetrofosmin cardiac single photon emission computed tomography in patients with coronary artery disease.

Authors:  W Acampa; A Cuocolo; P Sullo; A Varrone; E Nicolai; L Pace; M Petretta; M Salvatore
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.