Literature DB >> 11845127

Tetrofosmin imaging in the detection of myocardial viability in patients with previous myocardial infarction: comparison with sestamibi and Tl-201 scintigraphy.

Wanda Acampa1, Alberto Cuocolo, Mario Petretta, Andrea Bruno, Massimo Castellani, Andrea Finzi, Paolo Gerundini.   

Abstract

BACKGROUND: Technetium 99m tetrofosmin has been introduced as a myocardial perfusion agent, providing similar results to those of thallium 201 and sestamibi in the identification of patients with coronary artery disease. No data are available comparing tetrofosmin and sestamibi imaging in the identification of reversible left ventricular (LV) dysfunction in the same patients. This study compared the results of tetrofosmin, thallium, and sestamibi single photon emission computed tomography at rest in detection of myocardial viability in patients with previous myocardial infarction. METHODS AND
RESULTS: Seventeen patients with previous myocardial infarction who were undergoing coronary revascularization were studied. Echocardiography was performed at baseline and 3 months after revascularization to evaluate recovery of LV function. The optimal threshold cutoffs to separate reversible from irreversible dysfunction, as determined by receiver operating characteristic analysis, were 55% of peak activity for both tetrofosmin and sestamibi and 60% for thallium. In all asynergic segments (n = 77) analyzed, tetrofosmin uptake correlated with both sestamibi (r = 0.90, P <.0001) and thallium (r = 0.85, P <.0001) activity. The sensitivity and specificity for reversible dysfunction were, respectively, 70% and 70% for tetrofosmin, 70% and 66% for sestamibi, and 60% and 68% for thallium imaging (all P = not significant). The areas under the receiver operating characteristic curves constructed for tetrofosmin, thallium, and sestamibi activity were 0.74 +/- 0.06 (mean +/- SD), 0.75 +/- 0.06, and 0.74 +/- 0.06, respectively (all P = not significant). Concordance for detecting myocardial viability between tetrofosmin and thallium imaging was found in 67 regions (87%) (kappa = 0.74), and concordance between tetrofosmin and sestamibi imaging was found in 69 regions (90%) (kappa = 0.79).
CONCLUSIONS: The diagnostic performance of quantitative rest tetrofosmin single photon emission computed tomography in predicting functional recovery after revascularization is comparable to that of both thallium and sestamibi scintigraphy in patients with myocardial infarction and chronic LV dysfunction.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11845127     DOI: 10.1067/mnc.2002.118122

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  28 in total

1.  Extent of myocardial viability in regions of left ventricular dysfunction by rest-redistribution thallium-201 imaging: a powerful predictor of outcome.

Authors:  G A Beller; M Ragosta
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

2.  Rest-redistribution thallium-201 SPECT to detect myocardial viability.

Authors:  R Sciagrà; G M Santoro; G Bisi; P Pedenovi; P F Fazzini; A Pupi
Journal:  J Nucl Med       Date:  1998-03       Impact factor: 10.057

Review 3.  Current diagnostic techniques of assessing myocardial viability in patients with hibernating and stunned myocardium.

Authors:  V Dilsizian; R O Bonow
Journal:  Circulation       Date:  1993-01       Impact factor: 29.690

4.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

5.  Exercise-test Tc-99m tetrofosmin SPECT in patients with chronic ischemic left ventricular dysfunction: direct comparison with Ti-201 reinjection.

Authors:  E Nicolai; A Cuocolo; W Acampa; A Varrone; L Pace; M Salvatore
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

6.  Comparison between thallium-201 and technetium-99m methoxyisobutyl isonitrile defect size in single-photon emission computed tomography at rest, exercise and redistribution in coronary artery disease.

Authors:  J C Maublant; X Marcaggi; J R Lusson; J Y Boire; J C Cauvin; P Jacob; A Veyre; J Cassagnes
Journal:  Am J Cardiol       Date:  1992-01-15       Impact factor: 2.778

7.  Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.

Authors:  E E DePasquale; A C Nody; E G DePuey; E V Garcia; G Pilcher; C Bredlau; G Roubin; A Gober; A Gruentzig; P D'Amato
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

8.  Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography.

Authors:  T Marwick; B Willemart; A M D'Hondt; T Baudhuin; W Wijns; J M Detry; J Melin
Journal:  Circulation       Date:  1993-02       Impact factor: 29.690

9.  Adenosine coronary vasodilation quantitative technetium 99m methoxy isobutyl isonitrile myocardial tomography in the identification and localization of coronary artery disease.

Authors:  E Nicolai; A Cuocolo; L Pace; A Nappi; P Sullo; S Cardei; L Argenziano; F Squame; P J Ell; M Salvatore
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

10.  Comparison of rest thallium-201 imaging and rest technetium-99m sestamibi imaging for assessment of myocardial viability in patients with coronary artery disease and severe left ventricular dysfunction.

Authors:  G J Kauffman; T S Boyne; D D Watson; W H Smith; G A Beller
Journal:  J Am Coll Cardiol       Date:  1996-06       Impact factor: 24.094

View more
  11 in total

1.  FDG imaging should be considered the preferred technique for accurate assessment of myocardial viability: against.

Authors:  Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

2.  EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.

Authors:  B Hesse; K Tägil; A Cuocolo; C Anagnostopoulos; M Bardiés; J Bax; F Bengel; E Busemann Sokole; G Davies; M Dondi; L Edenbrandt; P Franken; A Kjaer; J Knuuti; M Lassmann; M Ljungberg; C Marcassa; P Y Marie; F McKiddie; M O'Connor; E Prvulovich; R Underwood; B van Eck-Smit
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-07       Impact factor: 9.236

Review 3.  SPECT and PET in ischemic heart failure.

Authors:  George Angelidis; Gregory Giamouzis; Georgios Karagiannis; Javed Butler; Ioannis Tsougos; Varvara Valotassiou; George Giannakoulas; Nikolaos Dimakopoulos; Andrew Xanthopoulos; John Skoularigis; Filippos Triposkiadis; Panagiotis Georgoulias
Journal:  Heart Fail Rev       Date:  2017-03       Impact factor: 4.214

4.  Added value of attenuation-corrected Tc-99m tetrofosmin SPECT for the detection of myocardial viability: comparison with FDG SPECT.

Authors:  Riemer H J A Slart; Jeroen J Bax; Wim J Sluiter; Dirk J van Veldhuisen; Pieter L Jager
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

5.  Fractional flow reserve and myocardial viability as assessed by SPECT perfusion scintigraphy in patients with prior myocardial infarction.

Authors:  Branko Beleslin; Milan Dobric; Dragana Sobic-Saranovic; Vojislav Giga; Jelena Stepanovic; Ana Djordjevic-Dikic; Milan Nedeljkovic; Sinisa Stojkovic; Vladan Vukcevic; Goran Stankovic; Dejan Orlic; Zorica Petrasinovic; Smiljana Pavlovic; Vladimir Obradovic; Miodrag Ostojic
Journal:  J Nucl Cardiol       Date:  2010-06-04       Impact factor: 5.952

6.  Comparison of the prognostic value of SPECT after nitrate administration and metabolic imaging by PET in patients with ischaemic left ventricular dysfunction.

Authors:  Anna Rita Sorrentino; Wanda Acampa; Mario Petretta; Ciro Mainolfi; Marco Salvatore; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-12-20       Impact factor: 9.236

7.  Comparison of nitrate augmented Tc-99m tetrofosmin gated SPECT imaging with FDG PET imaging for the assessment of myocardial viability in patients with severe left ventricular dysfunction.

Authors:  Senthil Raja; Baljinder Singh; Manoj Kumar Rohit; Kuruva Manohar; Raghava Kashyap; Anish Bhattacharya; B R Mittal
Journal:  J Nucl Cardiol       Date:  2012-08-08       Impact factor: 5.952

8.  Myocardial imaging with 99mTc-Tetrofosmin: Influence of post-stress acquisition time, regional radiotracer uptake, and wall motion abnormalities on the clinical result.

Authors:  Assuero Giorgetti; Annette Kusch; Mirta Casagranda; Irene D'Aragona Tagliavia; Paolo Marzullo
Journal:  J Nucl Cardiol       Date:  2009-12-15       Impact factor: 5.952

9.  Tc-99m tetrofosmin tomography after nitrate administration in patients with ischemic left ventricular dysfunction: relation to metabolic imaging by PET.

Authors:  Wei He; Wanda Acampa; Ciro Mainolfi; Francesco Menna; Anna Rita Sorrentino; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

10.  Assessment of Myocardial Scar; Comparison Between F-FDG PET, CMR and Tc-Sestamibi.

Authors:  Andrew Crean; Sadia N Khan; L Ceri Davies; Richard Coulden; David P Dutka
Journal:  Clin Med Cardiol       Date:  2009-06-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.