Literature DB >> 86580

Detection of suspicious cells and rejection of artefacts in cervical cytology using the Leyden Television Analysis System.

I Al, J S Ploem.   

Abstract

In slide based automation of cervical cytology the first stage of analysis involves finding possibly suspicious cells, or areas on the slide with these types of cells. By using a television based system such as the Leyden Television Analysis System (LEYTAS), a number of detection methods can be applied to rapidly screen a large number of fields automatically for suspicious cells. In this paper, results using a parameter based on increased nuclear DNA content of cells are given and a second detection method based on a chromatin pattern feature, called chromatin contrast, is discussed. Two blind trials on 41 positive and 22 negative cervical slides, using the Leyden Television Analysis System to detect suspicious cells with an increased nuclear DNA content, were promising. In 1 of the 41 positive cases no suspicious cells were found. In the negative specimens, suspicious cells were detected in 1 of 9 cases and 1 of 13 cases, with the two detection parameters investigated. These findings are discussed and some automatic artefact rejection procedures with preliminary results are given.

Mesh:

Substances:

Year:  1979        PMID: 86580     DOI: 10.1177/27.1.86580

Source DB:  PubMed          Journal:  J Histochem Cytochem        ISSN: 0022-1554            Impact factor:   2.479


  5 in total

1.  Cervical brush biopsy specimens suitable for DNA and oncoprotein analysis using flow cytometry.

Authors:  J Elias-Jones; P Hendy-Ibbs; H Cox; G I Evan; J V Watson
Journal:  J Clin Pathol       Date:  1986-05       Impact factor: 3.411

2.  Semiautomated evaluation of morphometric data on myoblasts and myotubes and the calculation of the relative DNA content with the television texture analysis system (TAS).

Authors:  P Bachmann; K Hinrichsen
Journal:  Histochemistry       Date:  1980

3.  Localized renal-cell carcinoma: detection of abnormal cells in peritumoral tissue. A cytophotometry and immunocytochemistry study.

Authors:  P Anton; H J Tanke; E P Allehoff; M A Kuczyk; C G Stief; U Jonas
Journal:  World J Urol       Date:  1995       Impact factor: 4.226

4.  Sensitive three-parameter flow-cytometric detection of abnormal cells in human cervical cancers: a pilot study.

Authors:  G Valet; M G Ormerod; H H Warnecke; G Benker; G Ruhenstroth-Bauer
Journal:  J Cancer Res Clin Oncol       Date:  1981       Impact factor: 4.553

5.  Flow cytometric quantitation of DNA and c-myc oncoprotein in archival biopsies of uterine cervix neoplasia.

Authors:  P Hendy-Ibbs; H Cox; G I Evan; J V Watson
Journal:  Br J Cancer       Date:  1987-03       Impact factor: 7.640

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.