Evaluation of intraocular pressure with Healon and Healon GV in sutureless cataract surgery with foldable lens implantation.

T Kohnen1, M von Ehr, E Schütte, D D Koch.   

Abstract

PURPOSE: To evaluate transient increases in intraocular pressure (IOP) after use of high-viscosity viscoelastic agents in cataract surgery.
SETTING: Military Hospital, Ulm, Germany.
METHODS: In a prospective, randomized study, we evaluated IOP following cataract surgery using two different viscoelastic substances (Healon, Healon GV). The viscosity of Healon GV is 10 times higher than that of Healon because of higher concentration and molecular weight. Patients having identical phacoemulsification procedures (sutureless clear corneal tunnel incision with foldable silicone lens implantation) (N = 60) and identical viscoelastic removal were assigned to groups of 15 based on viscoelastic used and removal time (20 or 40 seconds). Intraocular pressure was measured preoperatively and at 6, 24, 36, and 48 hours and 1 month postoperatively.
RESULTS: The highest mean IOP elevations in both viscoelastic groups were obtained at 24 hours postoperatively (2.9 mm Hg +/- 4.3 [SD] with Healon and 3.3 +/- 6.3 mm Hg with Healon GV). There were no statistically significant differences between the two viscoelastics and the two removal times during the entire follow-up period (unpaired t-test), but standard deviations were higher in the Healon GV groups at 6 and 24 hours. Two patients in the Healon groups and three in the Healon GV groups required medical treatment for IOP within the first 24 postoperative hours; however, all five patients had an IOP lower than 22 mm Hg on the second postoperative day.
CONCLUSIONS: Based on postoperative IOP, both viscoelastics can be equally well removed from the anterior chamber. Incidence of high IOP using high-viscosity hyaluronic acid is minimized by the described removal technique.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8656390     DOI: 10.1016/s0886-3350(96)80224-0

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

Review 1.  Do we need day-1 postoperative follow-up after cataract surgery?

Authors:  Andrzej Grzybowski; Piotr Kanclerz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-12-19       Impact factor: 3.117

2.  Increased intraocular pressure on the first postoperative day following resident-performed cataract surgery.

Authors:  J Y Kim; M-W Jo; S C Brauner; Z Ferrufino-Ponce; R Ali; S L Cremers; B An Henderson
Journal:  Eye (Lond)       Date:  2011-04-29       Impact factor: 3.775

3.  Intraocular pressure rise after small incision cataract surgery: a randomised intraindividual comparison of two dispersive viscoelastic agents.

Authors:  G Rainer; R Menapace; O Findl; B Kiss; V Petternel; M Georgopoulos; B Schneider
Journal:  Br J Ophthalmol       Date:  2001-02       Impact factor: 4.638

Review 4.  Impact of Ophthalmic Viscosurgical Devices in Cataract Surgery.

Authors:  Monali S Malvankar-Mehta; Angel Fu; Yasoda Subramanian; Cindy Hutnik
Journal:  J Ophthalmol       Date:  2020-10-20       Impact factor: 1.909

5.  Oral versus topical carbonic anhydrase inhibitors in ocular hypertension after scleral tunnel cataract surgery.

Authors:  Abdulmoghni Al-Barrag; Motaher Al-Shaer; Nabil Al-Matary; Mahfoud Bamashmous
Journal:  Clin Ophthalmol       Date:  2009-06-29

6.  Comparison of OVD and BSS for maintaining the anterior chamber during IOL implantation.

Authors:  Ho Young Lee; Yoon Jung Choy; Jong Seok Park
Journal:  Korean J Ophthalmol       Date:  2011-01-17

7.  Evaluation of a new method of irrigation and aspiration for removal of ophthalmic viscoelastic device during cataract surgery in a porcine model.

Authors:  Arisa Mitani; Takashi Suzuki; Yoshitaka Tasaka; Takahiro Uda; Yukako Hiramatsu; Shiro Kawasaki; Yuichi Ohashi
Journal:  BMC Ophthalmol       Date:  2014-11-07       Impact factor: 2.209

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.