Literature DB >> 21527959

Increased intraocular pressure on the first postoperative day following resident-performed cataract surgery.

J Y Kim1, M-W Jo, S C Brauner, Z Ferrufino-Ponce, R Ali, S L Cremers, B An Henderson.   

Abstract

PURPOSE: The aim of this study was to investigate the incidence of intraocular pressure (IOP) elevation after resident-performed cataract surgery and to determine variables, which influence postoperative day 1 (POD1) IOP.
METHODS: In all, 1111 consecutive cataract surgeries performed only by training residents between 1 July 2001 and 30 June 2006 were included. Elevated IOP was defined as ≥23 mm Hg. Surgeries were classified according to the presence of POD1-IOP elevation. Fisher's exact test and Student t-test were used to compare both groups. Multivariate analyses using generalized estimating equations were performed to investigate predictor variables associated with POD1-IOP elevation.
RESULTS: The average preoperative IOP was 16.0±3.2 mm Hg and the average POD1-IOP was 19.3±7.1 mm Hg, reflecting a significant increase in IOP (P<0.001, paired t-test). The incidence of POD1-IOP elevation ≥23 mm Hg was 22.0% (244/1111). Presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length were frequently encountered variables in the POD1-IOP elevation group (all P<0.05). Using a multivariate analysis, presence of glaucoma (P=0.004, OR=2.38; 95% confidence interval (95% CI)=1.31-4.30), presence of ocular hypertension (P=0.003, OR=6.09; 95% CI=1.81-20.47), higher preoperative IOP (P<0.001, OR=3.73; 95% CI=1.92-7.25), and longer axial length (P=0.01, OR=1.15; 95% CI=1.03-1.29) were significant predictive factors for POD1-IOP elevation.
CONCLUSIONS: IOP elevation on the first postoperative day following resident-performed cataract surgery occurred frequently (22.0%). Increased early postoperative IOP was associated with presence of glaucoma and ocular hypertension, higher preoperative IOP, and longer axial length.

Entities:  

Mesh:

Year:  2011        PMID: 21527959      PMCID: PMC3178167          DOI: 10.1038/eye.2011.93

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  48 in total

1.  Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen.

Authors:  Archana Bhan; Andrew C Browning; Sunil Shah; Robin Hamilton; Dinesh Dave; Harminder S Dua
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-05       Impact factor: 4.799

2.  Applanation tonometry and central corneal thickness.

Authors:  N Ehlers; T Bramsen; S Sperling
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-03

3.  Intraocular pressure rise after phacoemulsification surgery in glaucoma patients.

Authors:  Hitoshi Yasutani; Ken Hayashi; Hideyuki Hayashi; Fumihiko Hayashi
Journal:  J Cataract Refract Surg       Date:  2004-06       Impact factor: 3.351

4.  The early complications of cataract surgery: is routine review of patients 1 week after cataract extraction necessary?

Authors:  M J McKellar; M J Elder
Journal:  Ophthalmology       Date:  2001-05       Impact factor: 12.079

5.  Effects of extracapsular implant techniques on endothelial density.

Authors:  K J Hoffer
Journal:  Arch Ophthalmol       Date:  1982-05

6.  Intraoperative management of posterior capsule tears in phacoemulsification and intraocular lens implantation.

Authors:  H V Gimbel; R Sun; M Ferensowicz; E Anderson Penno; A Kamal
Journal:  Ophthalmology       Date:  2001-12       Impact factor: 12.079

7.  Revisiting early postoperative follow-up after phacoemulsification.

Authors:  Iqbal Ike K Ahmed; Christoph Kranemann; Mary Chipman; Faiz Malam
Journal:  J Cataract Refract Surg       Date:  2002-01       Impact factor: 3.351

8.  Role of intraocular pressure measurement on the day of phacoemulsification cataract surgery.

Authors:  Andrew C Browning; Amar Alwitry; Robin Hamilton; Alan Rotchford; Archana Bhan; Winfried M Amoaku
Journal:  J Cataract Refract Surg       Date:  2002-09       Impact factor: 3.351

9.  Analysis of risk factors that may be associated with progression from ocular hypertension to primary open angle glaucoma.

Authors:  John Landers; Ivan Goldberg; Stuart L Graham
Journal:  Clin Exp Ophthalmol       Date:  2002-08       Impact factor: 4.207

10.  Effect of topical brinzolamide 1% and brimonidine 0.2% on intraocular pressure after phacoemulsification.

Authors:  Altuğ Cetinkaya; Ahmet Akman; Yonca Aydin Akova
Journal:  J Cataract Refract Surg       Date:  2004-08       Impact factor: 3.351

View more
  14 in total

1.  Increased intraocular pressure on the first post-operative day following sutureless extracapsular cataract surgery in Africa.

Authors:  W H Dean; L Banda; E S Kambewa; J C Sherwin
Journal:  Eye (Lond)       Date:  2011-11-11       Impact factor: 3.775

2.  First postoperative day intraocular pressure rise in resident-performed cataract surgery.

Authors:  R Chaudhary; A Kadyan
Journal:  Eye (Lond)       Date:  2012-04-27       Impact factor: 3.775

3.  Predictive modeling of risk factors and complications of cataract surgery.

Authors:  Gregory L Gaskin; Suzann Pershing; Tyler S Cole; Nigam H Shah
Journal:  Eur J Ophthalmol       Date:  2015-12-17       Impact factor: 2.597

Review 4.  Ocular complications of perioperative anesthesia: a review.

Authors:  Rohan Bir Singh; Tanvi Khera; Victoria Ly; Chhavi Saini; Wonkyung Cho; Sukhman Shergill; Kanwar Partap Singh; Aniruddha Agarwal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-02-24       Impact factor: 3.117

5.  Is the 1-day postoperative IOP check needed post uncomplicated phacoemulsification in patients with glaucoma and ocular hypertension?

Authors:  A Gupta; S A Vernon
Journal:  Eye (Lond)       Date:  2015-02-20       Impact factor: 3.775

6.  Brimonidine-timolol versus brinzolamide-timolol for treatment of elevated intraocular pressure after phacoemulsification surgery.

Authors:  Selahattin Balsak; Ayhan Kaydu; Seyfettin Erdem; M Fuat Alakus; Zeynep Gursel Ozkurt
Journal:  Int Ophthalmol       Date:  2017-07-03       Impact factor: 2.031

7.  Changes in corneal thickness and corneal endothelial cell density after phacoemulsification cataract surgery: a double-blind randomized trial.

Authors:  Shahram Bamdad; Alireza Bolkheir; Mohammad Reza Sedaghat; Mahsa Motamed
Journal:  Electron Physician       Date:  2018-04-25

8.  Outcomes and favourable prognostic factors in patients of phacomorphic and phacolytic glaucoma managed by manual small-incision cataract surgery: A retrospective study.

Authors:  Shivkumar Chandrashekharan; Sabyasachi Chakrabarty; Meghana Tanwar; Bharadwaja Madhuvarasu; Mohammed Sithiq Uduman; Rengappa Ramakrishnan
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

9.  Results of cataract surgery in the very elderly population.

Authors:  Katarzyna Michalska-Małecka; Mariusz Nowak; Piotr Gościniewicz; Jacek Karpe; Ludmiła Słowińska-Łożyńska; Agnieszka Łypaczewska; Dorota Romaniuk
Journal:  Clin Interv Aging       Date:  2013-08-07       Impact factor: 4.458

10.  Cataract surgery outcome in patients with non-glaucomatous pseudoexfoliation.

Authors:  Praveen Venkatesha Sastry; Anuj Kumar Singal
Journal:  Rom J Ophthalmol       Date:  2017 Jul-Sep
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.