Literature DB >> 8654464

Radiation exposure to the hands of operators during angiographic procedures.

J Damilakis1, M Koukourakis, A Hatjidakis, S Karabekios, N Gourtsoyiannis.   

Abstract

The hands of those undertaking angiographic studies are close to the X-ray beam and may receive high doses. However, during recent years little information is available on these doses. The exposure to the left and right hand was measured with thermoluminescent dose meters during several conventional angiographic procedures. Mean doses to the left hand ranged from 0.24 to 0.96 mSv and to the right hand from 0.12 to 0.71 mSv, related to the type of procedure performed. The protection provided by new flexible lead gloves was estimated. The dose reduction with the glove was 19.5%. Operators can approach the dose limit to hands set by the International Commission on Radiological Protection (ICRP) during high workload. The data presented emphasize the importance of wearing lead gloves.

Mesh:

Year:  1995        PMID: 8654464     DOI: 10.1016/0720-048x(95)00688-m

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

1.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures.

Authors:  E P Efstathopoulos; I Pantos; M Andreou; A Gkatzis; E Carinou; C Koukorava; N L Kelekis; E Brountzos
Journal:  Br J Radiol       Date:  2011-01       Impact factor: 3.039

2.  Interventional Angiography: Radiation Protection for the Examiner by using Lead-free Gloves.

Authors:  Peter Kamusella; Fabian Scheer; Christopher Wilhelm Lüdtke; Philipp Wiggermann; Christian Wissgott; Reimer Andresen
Journal:  J Clin Diagn Res       Date:  2017-07-01

3.  Occupational radiation exposure in doctors: an analysis of exposure rates over 25 years.

Authors:  Amy R Sharkey; Parthivi Gambhir; Sepas Saraskani; Ross Walker; Ashcaan Hajilou; Paul Bassett; Navneet Sandhu; Peter Croasdale; Ian Honey; Athanasios Diamantopoulos; Vicky Goh
Journal:  Br J Radiol       Date:  2021-09-19       Impact factor: 3.039

4.  Evaluation of operator radioprotection using a new injection device during vertebroplasty.

Authors:  L Nguyen-Kim; C Fargeot; H Beaussier; S Payen; J Chiras
Journal:  Interv Neuroradiol       Date:  2013-05-21       Impact factor: 1.610

5.  Time to take the gloves off: the use of radiation reduction gloves can greatly increase patient dose.

Authors:  Alexander S Pasciak; A Kyle Jones
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.