Literature DB >> 8650720

Performance of carotid ultrasound in evaluating candidates for carotid endarterectomy is optimized by an approach based on clinical outcome rather than accuracy.

J L Wilterdink1, E Feldmann, J D Easton, R Ward.   

Abstract

BACKGROUND AND
PURPOSE: The best method of selecting endarterectomy candidates for cerebral angiography is controversial. Carotid duplex ultrasound (CDUS) is widely used, but its performance varies across institutions. The clinical utility of CDUS could be improved with test criteria based on patient outcome rather than test accuracy.
METHODS: In 155 carotid bifurcations studied by CDUS and cerebral angiography, the degree of angiographic stenosis was measured by a reader, blinded to CDUS, using the North American Symptomatic Carotid Endarterectomy Trial (NASCET) method. We calculated accuracy, sensitivity, and specificity for predicting > or = 70% angiographic carotid stenosis of different peak systolic frequencies (PSF) measured by CDUS and generated a receiver operator characteristic (ROC) curve. We used NASCET outcome data and published data on angiographic complications to define relative "costs" of false-positive and false-negative CDUS, and we determined the point on the ROC curve representing the CDUS criterion with the highest clinical utility. We compared projected morbidity and mortality rates for 1000 hypothetical endarterectomy candidates resulting from the use of the most accurate CDUS criterion versus the CDUS criterion with the highest clinical utility by ROC analysis.
RESULTS: While PSF > or = 8 kHz had the highest CDUS accuracy (93%), its projected stroke and death rate due to CDUS error was 10.4/1000. On the other hand, PSF > or = 7 kHz, defined by ROC analysis to have the highest clinical utility, had a lower morbidity and mortality rate of 6.8/1000.
CONCLUSIONS: The use of ROC analysis and available outcome data can improve the performance of CDUS in selecting endarterectomy candidates for cerebral angiography.

Entities:  

Mesh:

Year:  1996        PMID: 8650720     DOI: 10.1161/01.str.27.6.1094

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  3 in total

Review 1.  Ultrasound and angiography in the selection of patients for carotid endarterectomy.

Authors:  Andrei V Alexandrov
Journal:  Curr Cardiol Rep       Date:  2003-03       Impact factor: 2.931

2.  Combined use of color duplex ultrasonography and B-flow imaging for evaluation of patients with carotid artery stenosis.

Authors:  Muharrem Tola; Mehmet Yurdakul; Turhan Cumhur
Journal:  AJNR Am J Neuroradiol       Date:  2004 Nov-Dec       Impact factor: 3.825

Review 3.  Duplex ultrasound for diagnosing symptomatic carotid stenosis in the extracranial segments.

Authors:  Nicolle Cassola; Jose Cc Baptista-Silva; Luis Cu Nakano; Carolina Dq Flumignan; Ricardo Sesso; Vladimir Vasconcelos; Nelson Carvas Junior; Ronald Lg Flumignan
Journal:  Cochrane Database Syst Rev       Date:  2022-07-11
  3 in total