Literature DB >> 8633788

A microscale electrospray interface for on-line, capillary liquid chromatography/tandem mass spectrometry of complex peptide mixtures.

M T Davis1, D C Stahl, S A Hefta, T D Lee.   

Abstract

A microcapillary liquid chromatography (HPLC) system designed for the gradient elution of peptide and protein samples at flow rates < 1 microL/min has been coupled to a triple-sector quadrupole mass spectrometer via a simple sheathless electrospray interface (microspray). The microspray interface used a flame-drawn, uncoated, fused silica needle with tip outer diameters in the range of 15-20 microm and an opening less than 5 microm in diameter. Online sample filtration to prevent clogging of the drawn needle was accomplished by using a hydrophilic PVDF membrane filter integrated into the needle assembly. The spray potential (0.5-1 kV) was applied directly to the sample stream through the capillary union. Stable electrospray conditions were obtained over the full range of the gradient (0-90% acetonitrile in water) and was generally independent of flow rate. Both off-line and online analyses of proteins and peptide digest mixtures were performed at sample levels less than 10 fmol. HPLC parameters could be optimized for either rapid LC/MS analysis or enhanced performance in LC/MS/MS experiments by modulation of the eluting peak widths. Additionally, flow could be greatly reduced as selected components pass through the interface to prolong the time available to collect mass spectral data. The reduced spectral background and peak width manipulation facilitated the acquisition of peptide production spectra (MS/MS) using real-time, automated instrument control procedures.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8633788     DOI: 10.1021/ac00120a019

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  30 in total

1.  Mapping of ATP binding regions in poly(A) polymerases by photoaffinity labeling and by mutational analysis identifies a domain conserved in many nucleotidyltransferases.

Authors:  G Martin; P Jenö; W Keller
Journal:  Protein Sci       Date:  1999-11       Impact factor: 6.725

2.  De novo sequencing of peptides using MALDI/TOF-TOF.

Authors:  Alfred L Yergey; Jens R Coorssen; Peter S Backlund; Paul S Blank; Glen A Humphrey; Joshua Zimmerberg; Jennifer M Campbell; Marvin L Vestal
Journal:  J Am Soc Mass Spectrom       Date:  2002-07       Impact factor: 3.109

3.  A novel interface for variable flow nanoscale LC/MS/MS for improved proteome coverage.

Authors:  Johannes P C Vissers; R Kevin Blackburn; M Arthur Moseley
Journal:  J Am Soc Mass Spectrom       Date:  2002-07       Impact factor: 3.109

4.  Stable gradient nanoflow LC-MS.

Authors:  Bradley B Schneider; Xu Guo; Lorne M Fell; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2005-09       Impact factor: 3.109

5.  Targeted comparative proteomics by liquid chromatography-tandem Fourier ion cyclotron resonance mass spectrometry.

Authors:  Christophe Masselon; Ljiljana Pasa-Tolić; Nikola Tolić; Gordon A Anderson; Bogdan Bogdanov; Andrey N Vilkov; Yufeng Shen; Rui Zhao; Wei-Jun Qian; Mary S Lipton; David G Camp; Richard D Smith
Journal:  Anal Chem       Date:  2005-01-15       Impact factor: 6.986

Review 6.  Proteome research based on modern liquid chromatography--tandem mass spectrometry: separation, identification and quantification.

Authors:  T Fröhlich; G J Arnold
Journal:  J Neural Transm (Vienna)       Date:  2006-07-13       Impact factor: 3.575

7.  Targeted tandem mass spectrometry for high-throughput comparative proteomics employing NanoLC-FTICR MS with external ion dissociation.

Authors:  Hyuk Kang; Ljiljana Pasa-Tolić; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-05-03       Impact factor: 3.109

8.  Current-controlled nanospray ionization mass spectrometry.

Authors:  Alexei Gapeev; Alberto Berton; Daniele Fabris
Journal:  J Am Soc Mass Spectrom       Date:  2009-03-14       Impact factor: 3.109

9.  Data-controlled automation of liquid chromatography/tandem mass spectrometry analysis of peptide mixtures.

Authors:  D C Stahl; K M Swiderek; M T Davis; T D Lee
Journal:  J Am Soc Mass Spectrom       Date:  1996-06       Impact factor: 3.109

10.  Picoelectrospray ionization mass spectrometry using narrow-bore chemically etched emitters.

Authors:  Ioan Marginean; Keqi Tang; Richard D Smith; Ryan T Kelly
Journal:  J Am Soc Mass Spectrom       Date:  2014-01       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.