Endodontic measurements in digital radiographs acquired by a photostimulable, storage phosphor system.

E Borg1, H G Gröndahl.   

Abstract

Digora is a newly developed digital system for intraoral radiography utilizing photostimulable storage phosphor image plates. The aim was to test the quality of the system in respect to the visibility of endodontic files and root apices at different exposures. In teeth from five dry mandibular jaw sections, Hedstrom files no. 15 were placed with the file tip at varying distances from the apex. The specimens were covered with soft tissue equivalent material and placed behind a 2-cm thick polymethyl methacrylate cylinder filled with water. Distance from focus to image plate was 30 cm. Exposures were made at 60 kV and 7 mA at 7 timer settings from 16 ms to 1000 ms in 50% increments. All images were viewed from the monitor by each of 8 observers allowed to use available contrast enhancement facilities to obtain subjectively good image quality. Utilizing built-in measurement functions, distances from file tip and root apex, respectively, to a reference line were measured in 0.1 mm. For measurements between file tip and reference line, and root apex and reference line, there was no statistically significant difference between measurements made at the lowest exposure, compared to the second lowest exposure but there was a statistically significant difference compared to the 5 highest. Measurements at the second lowest exposure were not significantly different from those obtained at the 5 highest exposures. Interobserver variability expressed as standard deviation between observers showed the largest value for measurements obtained at the lowest exposure. The mean observed distances between the tip of the file and the root apex were calculated and showed no statistically significant differences between different exposures. We concluded that the Digora intraoral image plate system provided reliable endodontic measurements even at very low exposures.

Entities:  

Mesh:

Year:  1996        PMID: 8631285     DOI: 10.1111/j.1600-9657.1996.tb00090.x

Source DB:  PubMed          Journal:  Endod Dent Traumatol        ISSN: 0109-2502


  4 in total

1.  The use of high-resolution digital imaging technology for small diameter K-file length determination in endodontics.

Authors:  Bart Vandenberghe; Marius Bud; Asti Sutanto; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2009-05-19       Impact factor: 3.573

2.  Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses.

Authors:  R S de Molon; R G Batitucci; R Spin-Neto; G M Paquier; C E Sakakura; G M Tosoni; G Scaf
Journal:  Dentomaxillofac Radiol       Date:  2013-09-04       Impact factor: 2.419

3.  Different digital imaging techniques in dental practice.

Authors:  Amela Lacević; Edina Vranić
Journal:  Bosn J Basic Med Sci       Date:  2004-05       Impact factor: 3.363

4.  Correlation between clinical parameters characterising peri-implant and periodontal health: a practice-based research in Spain in a series of patients with implants installed 4-5 years ago.

Authors:  Roberto Lopez-Piriz; Araceli Morales; Maria-Jose Giménez; Antonio Bowen; Rafael Carroquino; Lorenzo Aguilar; Ignacio Corral; Cora del Val; Inmaculada González; Luis-Maria Ilzarbe; Juan-Ramon Maestre; Esteban Padullés; Francisco Torres-Lear; Juan-Jose Granizo; Fidel San-Román; Sofia Hernández; Jose Prieto
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.