Literature DB >> 8628665

Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR.

M A Shoffner1, J Cheng, G E Hvichia, L J Kricka, P Wilding.   

Abstract

The microreaction volumes of PCR chips (a microfabricated silicon chip bonded to a piece of flat glass to form a PCR reaction chamber) create a relatively high surface to volume ratio that increases the significance of the surface chemistry in the polymerase chain reaction (PCR). We investigated several surface passivations in an attempt to identify 'PCR friendly' surfaces and used those surfaces to obtain amplifications comparable with those obtained in conventional PCR amplification systems using polyethylene tubes. Surface passivations by a silanization procedure followed by a coating of a selected protein or polynucleotide and the deposition of a nitride or oxide layer onto the silicon surface were investigated. Native silicon was found to be an inhibitor of PCR and amplification in an untreated PCR chip (i.e. native slicon) had a high failure rate. A silicon nitride (Si(3)N(4) reaction surface also resulted in consistent inhibition of PCR. Passivating the PCR chip using a silanizing agent followed by a polymer treatment resulted in good amplification. However, amplification yields were inconsistent and were not always comparable with PCR in a conventional tube. An oxidized silicon (SiO(2) surface gave consistent amplifications comparable with reactions performed in a conventional PCR tube.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8628665      PMCID: PMC145622          DOI: 10.1093/nar/24.2.375

Source DB:  PubMed          Journal:  Nucleic Acids Res        ISSN: 0305-1048            Impact factor:   16.971


  15 in total

1.  Light-directed, spatially addressable parallel chemical synthesis.

Authors:  S P Fodor; J L Read; M C Pirrung; L Stryer; A T Lu; D Solas
Journal:  Science       Date:  1991-02-15       Impact factor: 47.728

Review 2.  Microfabrication techniques for integrated sensors and microsystems.

Authors:  K D Wise; K Najafi
Journal:  Science       Date:  1991-11-29       Impact factor: 47.728

Review 3.  Molecular self-assembly and nanochemistry: a chemical strategy for the synthesis of nanostructures.

Authors:  G M Whitesides; J P Mathias; C T Seto
Journal:  Science       Date:  1991-11-29       Impact factor: 47.728

4.  Micromachining a miniaturized capillary electrophoresis-based chemical analysis system on a chip.

Authors:  D J Harrison; K Fluri; K Seiler; Z Fan; C S Effenhauser; A Manz
Journal:  Science       Date:  1993-08-13       Impact factor: 47.728

5.  Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips.

Authors:  J Cheng; M A Shoffner; G E Hvichia; L J Kricka; P Wilding
Journal:  Nucleic Acids Res       Date:  1996-01-15       Impact factor: 16.971

6.  Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer.

Authors:  K A Erickson; P Wilding
Journal:  Clin Chem       Date:  1993-02       Impact factor: 8.327

7.  Manipulation and flow of biological fluids in straight channels micromachined in silicon.

Authors:  P Wilding; J Pfahler; H H Bau; J N Zemel; L J Kricka
Journal:  Clin Chem       Date:  1994-01       Impact factor: 8.327

Review 8.  Rationale for cost-effective laboratory medicine.

Authors:  A Robinson
Journal:  Clin Microbiol Rev       Date:  1994-04       Impact factor: 26.132

9.  Improvement in 'stat' laboratory turnaround time. A model continuous quality improvement project.

Authors:  E I Bluth; D J Lambert; T P Lohmann; D N Franklin; M Bourgeois; C G Kardinal; J R Dalovisio; M M Williams; A S Becker
Journal:  Arch Intern Med       Date:  1992-04

10.  Required technology breakthroughs to assume widely accepted biosensors.

Authors:  M Madou; M J Tierney
Journal:  Appl Biochem Biotechnol       Date:  1993 Apr-May       Impact factor: 2.926

View more
  23 in total

1.  Microchip module for blood sample preparation and nucleic acid amplification reactions.

Authors:  P K Yuen; L J Kricka; P Fortina; N J Panaro; T Sakazume; P Wilding
Journal:  Genome Res       Date:  2001-03       Impact factor: 9.043

2.  A miniature integrated device for automated multistep genetic assays.

Authors:  R C Anderson; X Su; G J Bogdan; J Fenton
Journal:  Nucleic Acids Res       Date:  2000-06-15       Impact factor: 16.971

3.  Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis.

Authors:  H Tian; L C Brody; J P Landers
Journal:  Genome Res       Date:  2000-09       Impact factor: 9.043

4.  Reduction of water evaporation in polymerase chain reaction microfluidic devices based on oscillating-flow.

Authors:  Alessandro Polini; Elisa Mele; Anna Giovanna Sciancalepore; Salvatore Girardo; Adriana Biasco; Andrea Camposeo; Roberto Cingolani; David A Weitz; Dario Pisignano
Journal:  Biomicrofluidics       Date:  2010-09-01       Impact factor: 2.800

5.  Effect of materials for micro-electro-mechanical systems on PCR yield.

Authors:  Cristina Potrich; Lorenzo Lunelli; Stefania Forti; Diego Vozzi; Laura Pasquardini; Lia Vanzetti; Cristina Panciatichi; Mariano Anderle; Cecilia Pederzolli
Journal:  Eur Biophys J       Date:  2009-05-20       Impact factor: 1.733

6.  Acetylated bovine serum albumin differentially inhibits polymerase chain reaction in microdevices.

Authors:  Naveen Ramalingam; Majid Ebrahimi Warkiani; Thomas Hai-Qing Gong
Journal:  Biomicrofluidics       Date:  2017-05-17       Impact factor: 2.800

7.  Flux characteristics of cell culture medium in rectangular microchannels.

Authors:  Zhonggang Feng; Shuhei Fukuda; Michio Yokoyama; Tatsuo Kitajima; Takao Nakamura; Mitsuo Umezu
Journal:  J Artif Organs       Date:  2011-04-20       Impact factor: 1.731

8.  Optimization of the performance of the polymerase chain reaction in silicon-based microstructures.

Authors:  T B Taylor; E S Winn-Deen; E Picozza; T M Woudenberg; M Albin
Journal:  Nucleic Acids Res       Date:  1997-08-01       Impact factor: 16.971

9.  A simple method of fabricating mask-free microfluidic devices for biological analysis.

Authors:  Xin Yi; Rimantas Kodzius; Xiuqing Gong; Kang Xiao; Weijia Wen
Journal:  Biomicrofluidics       Date:  2010-09-07       Impact factor: 2.800

10.  Sensitive, microliter PCR with consensus degenerate primers for Epstein Barr virus amplification.

Authors:  Christopher R Phaneuf; Kyudam Oh; Nikita Pak; D Curtis Saunders; Christina Conrardy; James P Landers; Suxiang Tong; Craig R Forest
Journal:  Biomed Microdevices       Date:  2013-04       Impact factor: 2.838

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.