Literature DB >> 21505818

Flux characteristics of cell culture medium in rectangular microchannels.

Zhonggang Feng1, Shuhei Fukuda, Michio Yokoyama, Tatsuo Kitajima, Takao Nakamura, Mitsuo Umezu.   

Abstract

Rectangular microchannels 50 μm high and 30, 40, 50, 60, or 70 μm wide were fabricated by adjusting the width of a gap cut in a polyethylene sheet 50 μm thick and sandwiching the sheet between an acrylic plate and a glass plate. Flux in the microchannels was measured under three different inner surface conditions: uncoated, albumin-coated, and confluent growth of rat fibroblasts on the bottom of the microchannels. The normalized flux in microchannels with cultured fibroblasts or albumin coating was significantly larger than that in the uncoated channels. The experimental data for all microchannels deviated from that predicted by classical hydrodynamic theory. At small aspect ratio the flux in the microchannels was larger than that predicted theoretically, whereas it became smaller at large aspect ratio. The aspect ratio rather than Reynolds number is the correct property for predicting the variation of the normalized friction factor. We postulate that two counteracting effects, rotation of large molecules and slip velocity at the corners of the microchannels, are responsible for the deviation. From these results we conclude that albumin coating should be carried out in the same way as when fabricating our integrating cell-culture system. The outcomes of this study are not only important for the design of our culture system, but also quite informative for general microfluidics.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21505818     DOI: 10.1007/s10047-011-0564-x

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  8 in total

Review 1.  Microfabrication in biology and medicine.

Authors:  J Voldman; M L Gray; M A Schmidt
Journal:  Annu Rev Biomed Eng       Date:  1999       Impact factor: 9.590

Review 2.  Bioanalysis in microfluidic devices.

Authors:  Julia Khandurina; András Guttman
Journal:  J Chromatogr A       Date:  2002-01-18       Impact factor: 4.759

3.  Shape Factor and Hydraulic Conductance in Noncircular Capillaries.

Authors:  T. W. Patzek; D. B. Silin
Journal:  J Colloid Interface Sci       Date:  2001-04-15       Impact factor: 8.128

4.  Effect of dynamic contact angle in a volume of fluid (VOF) model for a microfluidic capillary flow.

Authors:  Auro Ashish Saha; Sushanta K Mitra
Journal:  J Colloid Interface Sci       Date:  2009-08-09       Impact factor: 8.128

5.  Periodic "flow-stop" perfusion microchannel bioreactors for mammalian and human embryonic stem cell long-term culture.

Authors:  Natanel Korin; Avishay Bransky; Uri Dinnar; Shulamit Levenberg
Journal:  Biomed Microdevices       Date:  2009-02       Impact factor: 2.838

6.  Chip PCR. II. Investigation of different PCR amplification systems in microbabricated silicon-glass chips.

Authors:  J Cheng; M A Shoffner; G E Hvichia; L J Kricka; P Wilding
Journal:  Nucleic Acids Res       Date:  1996-01-15       Impact factor: 16.971

7.  Chip PCR. I. Surface passivation of microfabricated silicon-glass chips for PCR.

Authors:  M A Shoffner; J Cheng; G E Hvichia; L J Kricka; P Wilding
Journal:  Nucleic Acids Res       Date:  1996-01-15       Impact factor: 16.971

8.  Silicon micromachining to tissue engineer branched vascular channels for liver fabrication.

Authors:  S Kaihara; J Borenstein; R Koka; S Lalan; E R Ochoa; M Ravens; H Pien; B Cunningham; J P Vacanti
Journal:  Tissue Eng       Date:  2000-04
  8 in total
  1 in total

Review 1.  Journal of Artificial Organs 2011: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; A Myoui; M Nishimura; T Nishimura; S Tokunaga; Y Tomizawa; T Tomo; T Tsukiya; T Yamaoka
Journal:  J Artif Organs       Date:  2012-02-29       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.