Literature DB >> 8626166

Bending and torquing accuracy of the bending art system (BAS).

H Fischer-Brandies1, W Orthuber, L Pohle, D Sellenrieck.   

Abstract

With the bending art system (BAS) the computerized production of individual arch wires has become possible. The BAS consists of an intraoral camera, a computer program and a bending machine producing the archwire by consecutive bending and twisting procedures. This study examines the accuracy of the bending machine when using 0.016" x 0.016" and 0.016" x 0.022" steel wire of rectangular cross-section. Bending angles ranging from 6 degrees to 54 degrees, and torsion angles ranging from 2 degrees to 35 degrees were tested; also the minimum distance between these individual operations was determined. The bent pieces of wire were analysed in a 3D-coordinate gauging system. The 0.016" x 0.016" steel wire showed a mean measuring error of 0.62 degree in bending procedures and of 0.72 degree in torsion procedures, whereas the 0.016" x 0.022" steel wire showed an error of 0.87 degree with edgewise bendings and of 0.86 degree with torsions. To ensure this accuracy a minimum distance of 0.5 mm to 0.7 mm, depending on which kind of bending combination is used, between bending and torsion is required. The error could be reduced even further if a more constant wire material and a more accurate calibration of the bending machine were used. All in all the precision of the bending machine meets the clinical requirements.

Mesh:

Year:  1996        PMID: 8626166     DOI: 10.1007/bf02189044

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  7 in total

1.  [The surface roughness of orthodontic wires--a laser optical and profilometric study].

Authors:  A Hartel; C Bourauel; D Drescher; G P Schmuth
Journal:  Schweiz Monatsschr Zahnmed       Date:  1992

2.  [Development of standard Edgewise apparatus for a pre-torqued and pre-angulated bracket system].

Authors:  R P McLaughlin; J C Bennett
Journal:  Inf Orthod Kieferorthop       Date:  1990

3.  The straight-wire appliance. Explained and compared.

Authors:  L F Andrews
Journal:  J Clin Orthod       Date:  1976-03

4.  Structural responses of orthodontic wires in flexure from a proposed alternative to the existing specification test.

Authors:  R J Nikolai; W T Anderson; M L Messersmith
Journal:  Am J Orthod Dentofacial Orthop       Date:  1988-06       Impact factor: 2.650

5.  Straight wire: the next generation.

Authors:  T D Creekmore; R L Kunik
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-07       Impact factor: 2.650

6.  [A computer-controlled flexing test for determining the elastic parameters of highly flexible orthodontic wires].

Authors:  R Plietsch; C Bourauel; D Drescher; B Nellen
Journal:  Fortschr Kieferorthop       Date:  1994-04

7.  Elastic energy/stiffness ratios for selected orthodontic wires.

Authors:  J P Klump; M G Duncanson; R S Nanda; G F Currier
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-12       Impact factor: 2.650

  7 in total
  2 in total

1.  The force module for the bending art system. Preliminary results.

Authors:  H Fischer-Brandies; W Orthuber; M Ermert; A Hussmanns
Journal:  J Orofac Orthop       Date:  1998       Impact factor: 1.938

2.  Continuous arch wire technique using the bending art system.

Authors:  H Fischer-Brandies; W Orthuber; J Laibe; E Menzel
Journal:  J Orofac Orthop       Date:  1997       Impact factor: 1.938

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.