Fate of the native aorta after repair of acute type A dissection: a magnetic resonance imaging study.

N R Moore1, A J Parry, B Trottman-Dickenson, R Pillai, S Westaby.   

Abstract

OBJECTIVE: To determine late patency of the aortic false lumen and propensity for aneurysm formation after repair of type A dissection.
DESIGN: Retrospective follow up study.
SETTING: Regional cardiac surgical unit. PATIENTS: 28 patients after repair of type A dissection.
METHODS: Magnetic resonance imaging (MRI) was performed between 6 weeks and 12 months after operation.
RESULTS: A patent distal false lumen with demonstrable blood flow was found in 22 patients (78%). Only six patients had complete obliteration of the false lumen by thrombus. The conduct of operation did not influence this. Nine patients (32%) showed aneurysmal dilatation of the false lumen and three had a repeat operation.
CONCLUSIONS: So-called "successful repair" of aortic dissection does not obliterate the distal false lumen. MRI is a safe and effective radiological procedure for determining patency and dilatation in the false lumen. Patients with type A dissection with blood flow in the false lumen should be studied every 6 months to look for aneurysmal dilatation.

Entities:  

Mesh:

Year:  1996        PMID: 8624875      PMCID: PMC484224          DOI: 10.1136/hrt.75.1.62

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  14 in total

1.  Echocardiography in diagnosis of aortic dissection.

Authors:  R Erbel; R Engberding; W Daniel; J Roelandt; C Visser; H Rennollet
Journal:  Lancet       Date:  1989-03-04       Impact factor: 79.321

2.  Aortic dissection: sensitivity and specificity of MR imaging.

Authors:  B A Kersting-Sommerhoff; C B Higgins; R D White; C P Sommerhoff; M J Lipton
Journal:  Radiology       Date:  1988-03       Impact factor: 11.105

3.  MR imaging of the aorta after surgery for aortic dissection.

Authors:  R D White; D J Ullyot; C B Higgins
Journal:  AJR Am J Roentgenol       Date:  1988-01       Impact factor: 3.959

4.  Computed tomography of thoracic aortic dissection: accuracy and pitfalls.

Authors:  N Vasile; D Mathieu; K Keita; D Lellouche; G Bloch; J P Cachera
Journal:  J Comput Assist Tomogr       Date:  1986 Mar-Apr       Impact factor: 1.826

5.  The diagnosis of thoracic aortic dissection by noninvasive imaging procedures.

Authors:  C A Nienaber; Y von Kodolitsch; V Nicolas; V Siglow; A Piepho; C Brockhoff; D H Koschyk; R P Spielmann
Journal:  N Engl J Med       Date:  1993-01-07       Impact factor: 91.245

6.  Use of biological glue in acute aortic dissection. Preliminary clinical results with a new surgical technique.

Authors:  D Guilmet; J Bachet; B Goudot; C Laurian; F Gigou; O Bical; M Barbagelatta
Journal:  J Thorac Cardiovasc Surg       Date:  1979-04       Impact factor: 5.209

7.  Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically.

Authors:  M E DeBakey; C H McCollum; E S Crawford; G C Morris; J Howell; G P Noon; G Lawrie
Journal:  Surgery       Date:  1982-12       Impact factor: 3.982

8.  Composite graft repair of Marfan aneurysm of the ascending aorta: results in 100 patients.

Authors:  V L Gott; R E Pyeritz; D E Cameron; P S Greene; V A McKusick
Journal:  Ann Thorac Surg       Date:  1991-07       Impact factor: 4.330

9.  Effect of medical and surgical therapy on aortic dissection evaluated by transesophageal echocardiography. Implications for prognosis and therapy. The European Cooperative Study Group on Echocardiography.

Authors:  R Erbel; H Oelert; J Meyer; M Puth; S Mohr-Katoly; D Hausmann; W Daniel; S Maffei; A Caruso; F E Covino
Journal:  Circulation       Date:  1993-05       Impact factor: 29.690

10.  Surgical repair of type A aortic dissection by the circulatory arrest-graft inclusion technique in sixty-six patients.

Authors:  A C Galloway; S B Colvin; E A Grossi; M A Parish; A T Culliford; T Asai; N M Rofsky; J C Weinreb; S Shapiro; F G Baumann
Journal:  J Thorac Cardiovasc Surg       Date:  1993-05       Impact factor: 5.209

View more
  9 in total

Review 1.  Left ventricular assessment using real time three dimensional echocardiography.

Authors:  L Sugeng; L Weinert; R M Lang
Journal:  Heart       Date:  2003-11       Impact factor: 5.994

2.  Influence of operative strategy for the aortic arch in DeBakey type I aortic dissection - analysis of the German Registry for Acute Aortic Dissection type A (GERAADA).

Authors:  Jerry Easo; Ernst Weigang; Philipp P F Hölzl; Michael Horst; Isabell Hoffmann; Maria Blettner; Otto E Dapunt
Journal:  Ann Cardiothorac Surg       Date:  2013-03

3.  Descending endograft for DeBakey type 1 aortic dissection: pro.

Authors:  Paolo Berretta; Marco Di Eusanio
Journal:  Ann Cardiothorac Surg       Date:  2016-05

4.  When and how to replace the aortic arch for type A dissection.

Authors:  Roberto Di Bartolomeo; Alessandro Leone; Luca Di Marco; Davide Pacini
Journal:  Ann Cardiothorac Surg       Date:  2016-07

5.  Large airway obstruction by a chronic dissecting aortic aneurysm in the Marfan syndrome.

Authors:  M R Hargreaves; T J Gilbert; R Pillai; G Hart
Journal:  Postgrad Med J       Date:  1997-11       Impact factor: 2.401

6.  Cluster analysis of acute ascending aortic dissection provides novel insight into mechanisms of distal progression.

Authors:  Jennifer L Philip; Nilto C De Oliveira; Shahab A Akhter; Brooks L Rademacher; Christopher B Goodavish; Paul D DiMusto; Paul C Tang
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 7.  Acquired diseases of the thoracic aorta: role of MRI and MRA.

Authors:  Vincenzo Russo; Matteo Renzulli; Katia Buttazzi; Rossella Fattori
Journal:  Eur Radiol       Date:  2005-10-13       Impact factor: 7.034

8.  Fate of dissected arch vessels by adventitial inversion technique for acute type A aortic dissection repair.

Authors:  Yuriko Takeuchi; Ryo Suzuki; Hiroshi Kurazumi; Ryosuke Nawata; Toshiki Yokoyama; Sarii Tsubone; Yutaro Matsuno; Akihito Mikamo; Kimikazu Hamano
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

9.  Extent of preoperative false lumen thrombosis does not influence long-term survival in patients with acute type A aortic dissection.

Authors:  Magnus Larsen; Kristian Bartnes; Thomas T Tsai; Kim A Eagle; Arturo Evangelista; Christoph A Nienaber; Toru Suzuki; Rossella Fattori; James B Froehlich; Stuart Hutchison; Thoralf M Sundt; James L Januzzi; Eric M Isselbacher; Daniel G Montgomery; Truls Myrmel
Journal:  J Am Heart Assoc       Date:  2013-07-01       Impact factor: 5.501

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.