Polyethylene wear in Scanhip arthroplasty with a 22 or 32 mm head: 62 matched patients followed for 7-9 years.

U Kesteris1, T Ilchmann, H Wingstrand, R Onnerfalt.   

Abstract

We measured radiographic polyethylene wear in patients with Scanhip arthroplasty and no clinical or radiographic signs of loosening. The patients were divided into 2 groups according to head sizes. 32 patients (33 hips) had an implant with a 22 mm and 30 patients (34 hips) with a 32 mm head. They were followed for 7-9 years. The groups were matched for diagnosis, sex, weight, age, and time of follow-up. The mean linear wear with a 22 mm head was 1.1 mm and with a 32 mm head 1.5 mm (p 0.004), which corresponds to a yearly wear rate of 0.15 mm and 0.18 mm, respectively. The mean difference in volumetric wear was greater, 420 mm3, as compared to 1239 mm3.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8623564     DOI: 10.3109/17453679608994655

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  7 in total

1.  The influence of stress conditions on the wear of UHMWPE for total joint replacements.

Authors:  P S Barbour; D C Barton; J Fisher
Journal:  J Mater Sci Mater Med       Date:  1997-10       Impact factor: 3.896

2.  Less wear with aluminium-oxide heads than cobalt-chrome heads with ultra high molecular weight cemented polyethylene cups: a ten-year follow-up with radiostereometry.

Authors:  Jon Dahl; Per Söderlund; Bo Nivbrant; Lars Nordsletten; Stephan M Röhrl
Journal:  Int Orthop       Date:  2011-08-26       Impact factor: 3.075

3.  Activities of daily living after total hip arthroplasty. Is a 32-mm femoral head superior to a 26-mm head for improving daily activities?

Authors:  Isao Matsushita; Yuji Morita; Yoshiaki Ito; Ryuichi Gejo; Tomoatsu Kimura
Journal:  Int Orthop       Date:  2009-11-29       Impact factor: 3.075

4.  Modified minimally invasive two-incision total hip arthroplasty using large diameter femoral head.

Authors:  Kyung Soon Park; Taek Rim Yoon; Sang Yun Hwang; Keun Bae Lee
Journal:  Indian J Orthop       Date:  2012-01       Impact factor: 1.251

5.  More than 50% reduction of wear in polyethylene liners with alumina heads compared to cobalt-chrome heads in hip replacements: a 10-year follow-up with radiostereometry in 43 hips.

Authors:  Jon Dahl; Finnur Snorrason; Lars Nordsletten; Stephan M Röhrl
Journal:  Acta Orthop       Date:  2013-06-25       Impact factor: 3.717

6.  Wear of a sequentially annealed polyethylene acetabular liner.

Authors:  Trevor C Gascoyne; Martin J Petrak; Thomas R Turgeon; Eric R Bohm
Journal:  Acta Orthop       Date:  2014-08-20       Impact factor: 3.717

7.  Pelvic Discontinuity Caused by Acetabular Overreaming during Primary Total Hip Arthroplasty.

Authors:  Iori Takigami; Yoshiki Ito; Takashi Mizoguchi; Katsuji Shimizu
Journal:  Case Rep Orthop       Date:  2011-12-21
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.