Literature DB >> 862174

Location and size of acute transmural myocardial infarction estimated from thallium-201 scintiscans. A clinicopathological study.

F J Wackers, A E Becker, G Samson, E B Sokole, J B van der Schoot, A J Vet, K I Lie, D Durrer, H Wellens.   

Abstract

A clinicopathological study was performed in 23 patients who died from acute transmural myocardial infarction and who had been studied with thallium-201 during the acute phase. Twenty patients died within five days and three later than five days after scintigraphy. The scintigraphic location and the estimated size of infarction in vivo were correlated with postmortem findings. There was good agreement in 91% between scintigraphic and postmortem location of infarction and in 70% between the ECG and postmortem findings. The size of infarction as determined from computer-processed schematic drawings of postmortem slices of the heart correlated well with the size determined from processed schematic drawings of the scintiscans (r = 0.91 for anterior infarction, r = 0.97 for inferior infarction, r = 0.86 for anterior-inferior infarction). It is concluded that thallium-201 scintigraphy provided more precise location of infarction than the ECG and that the size of the scintigraphically abnormal area reflected the extent of necrotic myocardium.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 862174     DOI: 10.1161/01.cir.56.1.72

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  18 in total

1.  Quantification of myocardial ischemia and infarction with single photon emission computed tomography.

Authors:  H M Hoffmeister; H Hanke; R Unterberg; W Voelker; W Kaiser; W Müller-Schauenburg; K R Karsch
Journal:  Eur J Nucl Med       Date:  1989

Review 2.  Non-invasive assessment of the effects of drugs on acute myocardial infarct size in man.

Authors:  D Maclean
Journal:  Br J Clin Pharmacol       Date:  1979-06       Impact factor: 4.335

3.  Evaluation of thallium-201 exercise scintigraphy in coronary heart disease.

Authors:  R G Murray; J H McKillop; R G Bessent; J G Turner; A R Lorimer; I Hutton; W R Greig; T D Lawrie
Journal:  Br Heart J       Date:  1979-05

4.  Cardiovascular nuclear medicine and intensive care.

Authors:  P J Ell; R M Donaldson
Journal:  Intensive Care Med       Date:  1978-07       Impact factor: 17.440

5.  Single photon tomographic imaging of a standard heart phantom with 201T1: a gamma camera based system.

Authors:  J L Ritchie; S Larsson; A Israelson; P O Schnell; A Holmgren; D L Williams; J I Thorell
Journal:  Eur J Nucl Med       Date:  1982

6.  Correlation between ST elevation and Q waves on the predischarge electrocardiogram and the extent and location of MIBI perfusion defects in anterior myocardial infarction.

Authors:  Barak Zafrir; Nili Zafrir; Tuvia Ben Gal; Yehuda Adler; Zaza Iakobishvili; M Atiar Rahman; Yochai Birnbaum
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-04       Impact factor: 1.468

7.  The scintigraphic evaluation of myocardial infarction and regional ventricular performance using technetium-99m hexakis (t-butylisonitrile) technetium (I) (TBI): a new myocardial imaging agent.

Authors:  S Campbell; B L Holman; J M Kirshenbaum; E M Antman; J Lister-James; A Davison; J Kozlowski; R J English; A G Jones
Journal:  Eur J Nucl Med       Date:  1986

8.  Evaluation of bedside myocardial scintigraphy with 201Tl in acute myocardial infarction.

Authors:  M Decramer; P Devos; M De Roo; J Piessens; H De Geest
Journal:  Eur J Nucl Med       Date:  1982

9.  Correlation of an abnormal rest 201T1 myocardial image: pathological findings in cardiac transplant recipients.

Authors:  J H McKillop; M Billingham; J S Schroeder; I R McDougall
Journal:  Eur J Nucl Med       Date:  1982

10.  Scintigraphic anatomy of coronary artery disease in digital thallium-201 myocardial images.

Authors:  R J Wainwright
Journal:  Br Heart J       Date:  1981-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.