Literature DB >> 7106150

Correlation of an abnormal rest 201T1 myocardial image: pathological findings in cardiac transplant recipients.

J H McKillop, M Billingham, J S Schroeder, I R McDougall.   

Abstract

Rest myocardial 201T1 scintigraphy was undertaken in 15 males mean age 39 years (22-54) who had been accepted for cardiac transplantation. Complete pathological correlation was obtained in 14 after transplantation and in 1 who died before a suitable donor heart became available. The average time from scintigraphy to pathological evaluation was 42 days (9-103). All the 201T1 images were grossly abnormal and on the basis of these studies it was not possible to differentiate ischemic from idiopathic cardiomyopathy. Each of the three views of the 201T1 study was divided into three segments, therefore 135 areas were available for comparison (3 x 3 x 15). Eighty-eight of these were abnormal on scan and 78 of these were abnormal pathologically. The right ventricle was seen on all rest images but the degree of uptake bore no relationship to the measured thickness of the right ventricular wall. Structures such as the atrial wall and the enlarged papillary muscle were visualized in some patients. In two patients there was an improvement of the rest 201T1 image in delayed views and histologically these areas showed a mixture of muscle and fibrous tissue. The sensitivity of 201T1 imaging in this study was 89% and there was close correlation of the images with gross and microscopic pathological findings.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 7106150     DOI: 10.1007/BF00251474

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  15 in total

1.  Visualization of atrial myocardium with thallium-201: case report.

Authors:  M J Cowley; H C Coghlan; J R Logic
Journal:  J Nucl Med       Date:  1977-10       Impact factor: 10.057

2.  Diagnostic value of visualization of the right ventricle using thallium-201 myocardial imaging.

Authors:  F Khaja; M Alam; S Goldstein; D T Anbe; D S Marks
Journal:  Circulation       Date:  1979-01       Impact factor: 29.690

3.  Interpolative background subtraction.

Authors:  M L Goris; S G Daspit; P McLaughlin; J P Kriss
Journal:  J Nucl Med       Date:  1976-08       Impact factor: 10.057

4.  Myocardial imaging with thallium-201 at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography.

Authors:  J L Ritchie; G B Trobaugh; G W Hamilton; K L Gould; K A Narahara; J A Murray; D L Williams
Journal:  Circulation       Date:  1977-07       Impact factor: 29.690

5.  Can the extent of coronary artery disease be predicted from thallium-201 myocardial images?

Authors:  J H McKillop; R G Murray; J G Turner; R G Bessent; A R Lorimer; W R Greig
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

6.  Transient defects of resting thallium scans in patients with coronary artery disease.

Authors:  H Gewirtz; G A Beller; H W Strauss; R E Dinsmore; L M Zir; K A McKusick; G M Pohost
Journal:  Circulation       Date:  1979-04       Impact factor: 29.690

7.  Correlation of thallium-201 scintigrams with coronary anatomy: factors affecting region by region sensitivity.

Authors:  B M Massie; E H Botvinick; B H Brundage
Journal:  Am J Cardiol       Date:  1979-10       Impact factor: 2.778

8.  The significance of the abnormal rest thallium-201 myocardial image in coronary artery disease.

Authors:  J H McKillop; R G Murray; R G Bessent; J G Turner; W R Greig; A R Lorimer
Journal:  Eur J Nucl Med       Date:  1979-04-01

9.  Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease.

Authors:  I K Bailey; L S Griffith; J Rouleau; W Strauss; B Pitt
Journal:  Circulation       Date:  1977-01       Impact factor: 29.690

10.  The predictive value of myocardial perfusion scintigraphy after stress in patients without previous myocardial infarction.

Authors:  D A Turner; W E Battle; H Deshmukh; M A Colandrea; G J Snyder; E W Fordham; J W Messer
Journal:  J Nucl Med       Date:  1978-03       Impact factor: 10.057

View more
  2 in total

Review 1.  Myocardial scintigraphy--25 years after start.

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1988

2.  Responses of coronary arteries of cardiac transplant patients to acetylcholine.

Authors:  R D Fish; E G Nabel; A P Selwyn; P L Ludmer; G H Mudge; J M Kirshenbaum; F J Schoen; R W Alexander; P Ganz
Journal:  J Clin Invest       Date:  1988-01       Impact factor: 14.808

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.