Literature DB >> 8612441

Subcutaneous glucose concentration in humans. Real estimation and continuous monitoring.

F Sternberg1, C Meyerhoff, F J Mennel, F Bischof, E F Pfeiffer.   

Abstract

OBJECTIVE: To determine the real subcutaneous glucose concentration in healthy volunteers to help in the development of new calibration methods for subcutaneous glucosensors. RESEARCH DESIGN AND METHODS: We developed a new method to estimate the real subcutaneous glucose concentration based on the recirculation of phosphate-buffered saline (PBS) in a microdialysis probe inserted into the subcutaneous tissue. Tissue glucose diffuses into the probe until complete equilibration between the glucose concentration outside and inside the microdialysis probe is achieved. Later, the glucose content of the recirculated PBS is assessed in vitro. We applied the method in 10 healthy volunteers under fasting state and during a hyperglycemic clamp. In addition, we monitored the subcutaneous glucose with an enzymatic-amperometric glucosensor combined with a microdialysis probe.
RESULTS: The subcutaneous glucose concentration measured by the recirculation method was 72 +/- 6 and 78 +/- 6% of the blood glucose measured in the fasting state and during the hyperglycemic clamps, respectively. On the other hand, the glucosensor's signal correlated significantly with the blood glucose.
CONCLUSION: The recirculation method estimated the real subcutaneous glucose concentration, opening the way to develop new calibration procedures for subcutaneous glucosensors. However, a suitable calibration procedure is still lacking.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8612441     DOI: 10.2337/diacare.18.9.1266

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  11 in total

1.  A Realtime and Continuous Assessment of Cortisol in ISF Using Electrochemical Impedance Spectroscopy.

Authors:  Manju Venugopal; Sunil K Arya; Ganna Chornokur; Shekhar Bhansali
Journal:  Sens Actuators A Phys       Date:  2011-12-01       Impact factor: 3.407

2.  Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

Authors:  J G Wagner; D W Schmidtke; C P Quinn; T F Fleming; B Bernacky; A Heller
Journal:  Proc Natl Acad Sci U S A       Date:  1998-05-26       Impact factor: 11.205

3.  Feasibility of overnight closed-loop control based on hourly blood glucose measurements.

Authors:  Caroline Patte; Stefan Pleus; Paul Galley; Stefan Weinert; Cornelia Haug; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2012-07-01

4.  Efficacy determinants of subcutaneous microdose glucagon during closed-loop control.

Authors:  Steven J Russell; Firas H El-Khatib; David M Nathan; Edward R Damiano
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

5.  A feasibility study of bihormonal closed-loop blood glucose control using dual subcutaneous infusion of insulin and glucagon in ambulatory diabetic swine.

Authors:  Firas H El-Khatib; John Jiang; Edward R Damiano
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

6.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

Review 7.  Microdialysis techniques and microdialysis-based patient-near diagnostics.

Authors:  Mark Thomas O'Connell; Jan Krejci
Journal:  Anal Bioanal Chem       Date:  2022-01-14       Impact factor: 4.142

8.  Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

Authors:  Chao-Chun Zou; Li Liang; Fang Hong; Zheng-Yan Zhao
Journal:  World J Pediatr       Date:  2008-02       Impact factor: 2.764

9.  Feasibility of Factory Calibration for Subcutaneous Glucose Sensors in Subjects With Diabetes.

Authors:  Udo Hoss; Erwin S Budiman; Hanqing Liu; Mark P Christiansen
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

10.  Clinical efficacy of Professional Continuous Glucose Monitoring in improving glycemic control among children with Type 1 Diabetes Mellitus: An Open-label Randomized Control Trial.

Authors:  K V Raviteja; Rakesh Kumar; Devi Dayal; Naresh Sachdeva
Journal:  Sci Rep       Date:  2019-04-16       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.