Abstract

This study describes the functioning of a novel sensor to measure cortisol concentration in the interstitial fluid (ISF) of a human subject. ISF is extracted by means of vacuum pressure from micropores created on the stratum corneum layer of the skin. The pores are produced by focusing a near infrared laser on a layer of black dye material attached to the skin. The pores are viable for approximately three days after skin poration. Cortisol measurements are based on electrochemical impedance (EIS) technique. Gold microelectrode arrays functionalized with Dithiobis (succinimidyl propionate) self-assembled monolayer (SAM) have been used to fabricate an ultrasensitive, disposable, electrochemical cortisol immunosensor. The biosensor was successfully used for in-vitro measurement of cortisol in ISF. Tests in a laboratory setup show that the sensor exhibits a linear response to cortisol concentrations in the range 1 pm to 100 nM. A small pilot clinical study showed that in-vitro immunosensor readings, when compared with commercial evaluation using enzyme-linked immunoassay (ELISA) method, correlated well with cortisol levels in saliva and ISF. Further, circadian rhythm could be established between the subject's ISF and the saliva samples collected over 24 hours time-period. Cortisol levels in ISF were found reliably higher than in saliva. This Research establishes the feasibility of using impedance based biosensor architecture for a disposable, wearable cortisol detector. The projected commercial in-vivo real-time cortisol sensor device, besides being minimally invasive, will allow continuous ISF harvesting and cortisol monitoring over 24 hours even when the subject is asleep. Forthcoming, this sensor could be interfaced to a wireless health monitoring system that could transfer sensor data over existing wide-area networks such as the internet and a cellular phone network to enable real-time remote monitoring of subjects.

Entities:  

Year:  2011        PMID: 22163154      PMCID: PMC3234992          DOI: 10.1016/j.sna.2011.04.028

Source DB:  PubMed          Journal:  Sens Actuators A Phys        ISSN: 0924-4247            Impact factor:   3.407


  19 in total

1.  A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements.

Authors:  Philip J Stout; Joel R Racchini; Michael E Hilgers
Journal:  Diabetes Technol Ther       Date:  2004-10       Impact factor: 6.118

2.  A fluorimetric assay for cortisol.

Authors:  Daniel Appel; Rolf D Schmid; Calin-Aurel Dragan; Matthias Bureik; Vlada B Urlacher
Journal:  Anal Bioanal Chem       Date:  2005-10-12       Impact factor: 4.142

3.  Urinary high performance reverse phase chromatography cortisol and cortisone analyses before and at the end of a race in elite cyclists.

Authors:  Rosalba Gatti; Enrico Cappellin; Barbara Zecchin; Giorgia Antonelli; Paolo Spinella; Franco Mantero; Elio Franco De Palo
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2005-09-25       Impact factor: 3.205

4.  Immunosensors: The next generation.

Authors:  A P Turner
Journal:  Nat Biotechnol       Date:  1997-05       Impact factor: 54.908

5.  Increased expression of 11beta-hydroxysteroid dehydrogenase type 1 in type 2 diabetic myotubes.

Authors:  B M Abdallah; H Beck-Nielsen; M Gaster
Journal:  Eur J Clin Invest       Date:  2005-10       Impact factor: 4.686

Review 6.  Clinical usefulness of the glucose concentration in the subcutaneous tissue--properties and pitfalls of electrochemical biosensors.

Authors:  U Fischer; K Rebrin; T von Woedtke; P Abel
Journal:  Horm Metab Res       Date:  1994-11       Impact factor: 2.936

7.  Antibody functionalized interdigitated micro-electrode (IDmicroE) based impedimetric cortisol biosensor.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Analyst       Date:  2010-06-29       Impact factor: 4.616

8.  Immobilization of DNA onto poly(dimethylsiloxane) surfaces and application to a microelectrochemical enzyme-amplified DNA hybridization assay.

Authors:  Daojun Liu; Robbyn K Perdue; Li Sun; Richard M Crooks
Journal:  Langmuir       Date:  2004-07-06       Impact factor: 3.882

9.  Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum.

Authors:  Suzanne Gebhart; Mark Faupel; Richard Fowler; Candis Kapsner; Daniel Lincoln; Valarie McGee; John Pasqua; Leigh Steed; Michael Wangsness; Fan Xu; Madeleine Vanstory
Journal:  Diabetes Technol Ther       Date:  2003       Impact factor: 6.118

10.  Data-mining analysis suggests an epigenetic pathogenesis for type 2 diabetes.

Authors:  Jonathan D Wren; Harold R Garner
Journal:  J Biomed Biotechnol       Date:  2005-06-30
View more
  11 in total

Review 1.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

2.  Sampling interstitial fluid from human skin using a microneedle patch.

Authors:  Pradnya P Samant; Megan M Niedzwiecki; Nicholas Raviele; Vilinh Tran; Juan Mena-Lapaix; Douglas I Walker; Eric I Felner; Dean P Jones; Gary W Miller; Mark R Prausnitz
Journal:  Sci Transl Med       Date:  2020-11-25       Impact factor: 17.956

3.  Quantification of cortisol in human eccrine sweat by liquid chromatography - tandem mass spectrometry.

Authors:  Min Jia; Wade M Chew; Yelena Feinstein; Perry Skeath; Esther M Sternberg
Journal:  Analyst       Date:  2016-03-21       Impact factor: 4.616

Review 4.  Systems Chronotherapeutics.

Authors:  Annabelle Ballesta; Pasquale F Innominato; Robert Dallmann; David A Rand; Francis A Lévi
Journal:  Pharmacol Rev       Date:  2017-04       Impact factor: 25.468

Review 5.  Electrochemical sensing of cortisol: a recent update.

Authors:  Aparajita Singh; Ajeet Kaushik; Rajesh Kumar; Madhavan Nair; Shekhar Bhansali
Journal:  Appl Biochem Biotechnol       Date:  2014-04-11       Impact factor: 2.926

6.  Carbon fiber based electrochemical sensor for sweat cortisol measurement.

Authors:  M Sekar; M Pandiaraj; S Bhansali; N Ponpandian; C Viswanathan
Journal:  Sci Rep       Date:  2019-01-23       Impact factor: 4.379

7.  Transitioning from acute to chronic pain: a simulation study of trajectories of low back pain.

Authors:  Jianzhong Su; Ying Du; Kelley Bevers; Pengcheng Xiao; John Licciardone; Marco Brotto; Robert J Gatchel
Journal:  J Transl Med       Date:  2019-09-06       Impact factor: 5.531

8.  Automated-immunosensor with centrifugal fluid valves for salivary cortisol measurement.

Authors:  Masaki Yamaguchi; Hiroki Katagata; Yuki Tezuka; Daisuke Niwa; Vivek Shetty
Journal:  Sens Biosensing Res       Date:  2014-07-09

9.  Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform.

Authors:  Jayoung Kim; Juliane R Sempionatto; Somayeh Imani; Martin C Hartel; Abbas Barfidokht; Guangda Tang; Alan S Campbell; Patrick P Mercier; Joseph Wang
Journal:  Adv Sci (Weinh)       Date:  2018-08-02       Impact factor: 16.806

10.  Electrochemical immunoassay for the detection of stress biomarkers.

Authors:  Jwan O Abdulsattar; Gillian M Greenway; Jay D Wadhawan
Journal:  Heliyon       Date:  2020-03-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.