Literature DB >> 8608728

Aequorea green fluorescent protein analysis by flow cytometry.

J D Ropp1, C J Donahue, D Wolfgang-Kimball, J J Hooley, J Y Chin, R A Hoffman, R A Cuthbertson, K D Bauer.   

Abstract

The isolation and expression of the cDNA for the green fluorescent protein (GFP) from the bioluminescent jellyfish Aequorea victoria has highlighted its potential use as a marker for gene expression in a variety of cell types (Chalfie et al.: Science 263: 802-805, 1994). The longer wavelength peak (470 nm) of GFP's bimodal absorption spectrum better matches standard fluorescein filter sets; however, it has a considerably lower amplitude than the major absorption peak at 395. In an effort to increase the sensitivity of GFP with routinely available instrumentation, Heim et al. (Nature 373:663-664, 1995) have generated a GFP mutant (serine-65 to threonine; S65T-GFP) which possesses a single absorption peak centered at 490 nm. We have constructed this mutant in order to determine whether it or wild-type GFP (wt-GFP) afforded greater sensitivity when excited near their respective absorption maxima. Using the conventionally available 488 nm and ultraviolet (UV) laser lines from the argon ion laser as well as the 407 nm line from a krypton ion laser with enhanced violet emission, we were able to closely match the absorption maxima of both the S65T and wild-type forms of Aequorea GFP and analyze differences in fluorescence intensity of transiently transfected 293 cells with flow cytometry. The highest fluorescence signal was observed with 488 nm excitation of S65T-GFP relative to all other laser line/GFP pairs. The wt-GFP fluorescence intensity, in contrast, was significantly higher at 407 nm relative to either 488 nm or UV. These results were consistent with parallel spectrofluorometric analysis of the emission spectrum for wt-GFP and S65T-GFP. The relative contribution of cellular autofluorescence at each wavelength was also investigated and shown to be significantly reduced at 407 nm relative to either UV or 488 nm.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8608728     DOI: 10.1002/cyto.990210402

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  9 in total

1.  A flow cytometric protocol for titering recombinant adenoviral vectors containing the green fluorescent protein.

Authors:  D C Hitt; J L Booth; V Dandapani; L R Pennington; J M Gimble; J Metcalf
Journal:  Mol Biotechnol       Date:  2000-03       Impact factor: 2.695

2.  An experimental solution for the Luria-Delbrück fluctuation problem in measuring hypermutation rates.

Authors:  J Bachl; M Dessing; C Olsson; R C von Borstel; C Steinberg
Journal:  Proc Natl Acad Sci U S A       Date:  1999-06-08       Impact factor: 11.205

Review 3.  Reporter systems for in vivo tracking of lactic acid bacteria in animal model studies.

Authors:  Winschau F van Zyl; Shelly M Deane; Leon M T Dicks
Journal:  Gut Microbes       Date:  2015

Review 4.  Flow cytometry applications in pharmacodynamics and drug delivery.

Authors:  M Ramanathan
Journal:  Pharm Res       Date:  1997-09       Impact factor: 4.200

5.  Simultaneous fluorescence-activated cell sorter analysis of two distinct transcriptional elements within a single cell using engineered green fluorescent proteins.

Authors:  M T Anderson; I M Tjioe; M C Lorincz; D R Parks; L A Herzenberg; G P Nolan; L A Herzenberg
Journal:  Proc Natl Acad Sci U S A       Date:  1996-08-06       Impact factor: 11.205

Review 6.  Flow cytometry and cell sorting of heterogeneous microbial populations: the importance of single-cell analyses.

Authors:  H M Davey; D B Kell
Journal:  Microbiol Rev       Date:  1996-12

7.  Functional analysis of human tRNA isodecoders.

Authors:  Renaud Geslain; Tao Pan
Journal:  J Mol Biol       Date:  2009-12-21       Impact factor: 5.469

8.  Simultaneous monitoring of cell number and metabolic activity of specific bacterial populations with a dual gfp-luxAB marker system.

Authors:  A Unge; R Tombolini; L Molbak; J K Jansson
Journal:  Appl Environ Microbiol       Date:  1999-02       Impact factor: 4.792

9.  An approach for characterizing and comparing hyperspectral microscopy systems.

Authors:  Naga S Annamdevula; Brenner Sweat; Peter Favreau; Ashley S Lindsey; Diego F Alvarez; Thomas C Rich; Silas J Leavesley
Journal:  Sensors (Basel)       Date:  2013-07-19       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.