Literature DB >> 8596834

Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung.

E A Kazerooni1, F T Lim, A Mikhail, F J Martinez.   

Abstract

PURPOSE: To determine risk factors for pneumothorax and chest tube placement associated with computed tomography (CT)-guided transthoracic needle aspiration biopsy (TNAB) of the lung.
METHODS: One hundred twenty-one consecutive CT-guided TNAB procedures were performed in 117 patients. Patient age, sex, number of needle passes and pleural planes traversed, lesion size, distance of lesion from the pleura, and results of pulmonary function tests were analyzed as single and multiple dependent variables for pneumothorax and chest tube placement.
RESULTS: Pneumothorax occurred in 54 of 121 procedures (44.6%); a chest tube was required in 18 cases (14.9%). Increased lesion depth was the most significant predictor of pneumothorax (P = .002). Smaller lesion size also correlated with increased risk of pneumothorax (P = .04). Among patients with pneumothorax, a significantly higher frequency of chest tube placement was seen in those with severe obstructive lung disease, as measured by percentage of predicted FEV1 (forced expiratory volume in 1 second) (51% in patients requiring a chest tube vs 81% in those not requiring a chest tube, P = .006) and FEV1/FVC (forced vital capacity) (x100) (45% vs 66%, P = .001).
CONCLUSION: Increased lesion depth and smaller lesion size correlated strongly with the development of pneumothorax. Once pneumothorax occurred, chest tube placement related to the severity of the patient's obstructive lung disease.

Entities:  

Mesh:

Year:  1996        PMID: 8596834     DOI: 10.1148/radiology.198.2.8596834

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  64 in total

1.  Guidelines for radiologically guided lung biopsy.

Authors:  A Manhire; M Charig; C Clelland; F Gleeson; R Miller; H Moss; K Pointon; C Richardson; E Sawicka
Journal:  Thorax       Date:  2003-11       Impact factor: 9.139

2.  Transthoracic needle biopsy.

Authors:  Katherine R Birchard
Journal:  Semin Intervent Radiol       Date:  2011-03       Impact factor: 1.513

3.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

4.  Evaluation of chronic infectious interstitial pulmonary disease in children by low-dose CT-guided transthoracic lung biopsy.

Authors:  Christoph M Heyer; Stefan P Lemburg; Thomas Kagel; Klaus-Michael Mueller; Thomas G Nuesslein; Christian H L Rieger; Volkmar Nicolas
Journal:  Eur Radiol       Date:  2005-01-26       Impact factor: 5.315

5.  Predictive factors of diagnostic accuracy of CT-guided transthoracic fine-needle aspiration for solid noncalcified, subsolid and mixed pulmonary nodules.

Authors:  Massimo De Filippo; Luca Saba; Giorgio Concari; Rita Nizzoli; Lilia Ferrari; Marcello Tiseo; Andrea Ardizzoni; Nicola Sverzellati; Ilaria Paladini; Chiara Ganazzoli; Luca Maria Sconfienza; Giampaolo Carrafiello; Luca Brunese; Eugenio Annibale Genovese; Luca Ampollini; Paolo Carbognani; Michele Rusca; Maurizio Zompatori; Cristina Rossi
Journal:  Radiol Med       Date:  2013-07-25       Impact factor: 3.469

6.  A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety.

Authors:  Daniel Yaffe; Matthew Koslow; Hassan Haskiya; David Shitrit
Journal:  Eur Radiol       Date:  2015-04-23       Impact factor: 5.315

7.  Comparison of fully automated and semi-automated biopsy needles for lung biopsy under CT fluoroscopic guidance.

Authors:  R Yoshimatsu; T Yamagami; O Tanaka; H Miura; T Tanaka; T Suzuki; T Nishimura
Journal:  Br J Radiol       Date:  2011-08-09       Impact factor: 3.039

8.  Diagnostic performance of percutaneous lung biopsy using automated biopsy needles under CT-fluoroscopic guidance for ground-glass opacity lesions.

Authors:  T Yamagami; R Yoshimatsu; H Miura; K Yamada; A Takahata; T Matsumoto; T Hasebe
Journal:  Br J Radiol       Date:  2013-02       Impact factor: 3.039

Review 9.  Ultrathin needle (25 G) aspiration lung biopsy: diagnostic accuracy and complication rates.

Authors:  Anastasia Oikonomou; Frederick R Matzinger; Jean M Seely; Carole J Dennie; Peter J Macleod
Journal:  Eur Radiol       Date:  2003-10-09       Impact factor: 5.315

10.  Chest computed tomography (CT) immediately after CT-guided transthoracic needle aspiration biopsy as a predictor of overt pneumothorax.

Authors:  Tae June Noh; Chang Hoon Lee; Young Ae Kang; Sung-Youn Kwon; Ho-Il Yoon; Tae Jung Kim; Kyung Won Lee; Jae Ho Lee; Choon-Taek Lee
Journal:  Korean J Intern Med       Date:  2009-11-27       Impact factor: 2.884

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.