Literature DB >> 8594505

Enlargement of incision width during phacoemulsification and folded intraocular lens implant surgery.

R F Steinert1, J Deacon.   

Abstract

PURPOSE: The authors investigated the dimensional stability of incisions during phacoemulsification and small-incision intraocular lens (IOL) implantation.
METHODS: Forty-six eyes undergoing temporal clear corneal phacoemulsification and folded silicone IOL implantation were measured with an internal-incision gauge after initial keratome entry, cataract removal, and folded IOL implantation.
RESULTS: The initial incision created by a diamond keratome was wider than the physical keratome width by a mean of 0.16 mm. After completion of phacoemulsification and irrigation/aspiration, the incision further widened by a mean of 0.09 mm. Both forceps insertion of a three-piece silicone IOL and injector insertion of a plate haptic silicone IOL resulted in further incision enlargement by a mean of 0.26 mm. Widening the incision before IOL insertion did not eliminate even further incision expansion during the IOL insertion.
CONCLUSIONS: The phacoemulsification incision enlarges at each step of the procedure. Irreversible incision stretching or incision tearing occurs, rather than reversible elastic incision deformation. Clinical studies that assume the initial keratome size equals the final incision size may be erroneous.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8594505     DOI: 10.1016/s0161-6420(96)30713-6

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  4 in total

Review 1.  [Incisions for biaxial and coaxial microincision cataract surgery].

Authors:  M Müller; T Kohnen
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

2.  Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study.

Authors:  S Khokhar; R Sharma; B Patil; N Aron; S Gupta
Journal:  Eye (Lond)       Date:  2014-07-18       Impact factor: 3.775

3.  Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector.

Authors:  Hisanori Imai; Ayaka Fujii; Emiko Tani; Atsushi Azumi
Journal:  J Ophthalmol       Date:  2016-02-17       Impact factor: 1.909

4.  Comparison of surgically induced astigmatisms after clear corneal incisions of different sizes.

Authors:  Sung Chur Moon; Tarek Mohamed; I Howard Fine
Journal:  Korean J Ophthalmol       Date:  2007-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.