Literature DB >> 8593985

Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics--a technique reexamined: two case reports.

H Salama1, L F Rose, M Salama, N J Betts.   

Abstract

A load-free healing period has been advocated as a prerequisite to achieving osseointegration. This article reports two cases in which immediate loading of a specially designated additional, or "expendable," set of titanium root-form implants was successfully utilized to support provisional fixed restorations in the maxilla and the mandible. This immediate-loading protocol is suggested as a reliable adjunctive therapeutic modality for offering implant patients access to fixed interim restorations during the healing phase of the primary fixtures. Another advantage of this approach is that it provides protection from potential transmucosal overload of the primary implants as well as any sites undergoing osseous regenerative procedures.

Entities:  

Mesh:

Year:  1995        PMID: 8593985

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  10 in total

Review 1.  Implants in bone: part I. A current overview about tissue response, surface modifications and future perspectives.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-24

2.  Clinical and radiographic evaluation of copolymerized Polylactic/polyglycolic acids as a bone filler in combination with a cellular dermal matrix graft around immediate implants.

Authors:  Mahitab M Soliman; Azza Abdulrahman Zaki; Hanaa Mohamed El Gazaerly; Ammar Al Shemmrani; Abd El Latif Sorour
Journal:  Int J Health Sci (Qassim)       Date:  2014-10

3.  A comparative analysis of periimplant bone levels of immediate and conventionally loaded implants.

Authors:  G K Thapliyal; V R Pawar
Journal:  Med J Armed Forces India       Date:  2012-09-14

4.  Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report.

Authors:  Jun-Won Hong; Seung-Geun Ahn; Dae-Ho Leem; Jae-Min Seo
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

5.  Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study.

Authors:  Mariano Herrero-Climent; Rocio Santos-García; Reyes Jaramillo-Santos; Manuel-Maria Romero-Ruiz; Ana Fernández-Palacin; Pedro Lázaro-Calvo; Pedro Bullón; Jose-Vicente Ríos-Santos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-11-01

6.  Soft Tissue Management on Pontic and Implant Sites Before Implants Insertion.

Authors:  Carlos A Jurado; Chin-Chuan Fu; Luis G Guzman; Jose Villalobos-Tinoco; Akimasa Tsujimoto
Journal:  Cureus       Date:  2022-04-30

7.  Zygomatic approach with single-piece implants: A technical note.

Authors:  Vivek Gaur; Anita Gala Doshi; Lukasz Palka
Journal:  Natl J Maxillofac Surg       Date:  2022-04-20

8.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11

9.  FEM Analysis of Mandibular Prosthetic Overdenture Supported by Dental Implants: Evaluation of Different Retention Methods.

Authors:  M Cicciù; G Cervino; E Bramanti; F Lauritano; G Lo Gudice; L Scappaticci; A Rapparini; E Guglielmino; G Risitano
Journal:  Comput Math Methods Med       Date:  2015-12-21       Impact factor: 2.238

10.  A Retrospective Study on Insertion Torque and Implant Stability Quotient (ISQ) as Stability Parameters for Immediate Loading of Implants in Fresh Extraction Sockets.

Authors:  Giuseppe Bavetta; Giorgio Bavetta; Valentina Randazzo; Alessio Cavataio; Carlo Paderni; Vincenzo Grassia; Gianna Dipalma; Ciro Gargiulo Isacco; Antonio Scarano; Danila De Vito; Stefania Cantore; Andrea Ballini; Francesco Inchingolo
Journal:  Biomed Res Int       Date:  2019-11-03       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.