Literature DB >> 8591621

Magnetic resonance angiography of intravascular endoprostheses: investigation of three devices.

J P Laissy1, C Grand, C Matos, J Struyven, J F Berger, E Schouman-Claeys.   

Abstract

PURPOSE: To assess the value of magnetic resonance angiography (MRA) in the evaluation of vascular patency after intravascular endoprosthesis placement.
METHODS: Three different metallic stents (Wallstent, Strecker, Palmaz) were studied in vitro, and in vivo in six patients with spin-echo (SE) and gradient-echo (GRE) MR imaging. Time-of-flight, two-dimensional (2D) gadolinium-enhanced MRA was performed with GRE and flow-compensation technique, and reconstructed with a maximum-intensity projection (MIP) algorithm. MRA was compared to digital angiograms.
RESULTS: In vitro studies demonstrated that the signal intensity (SI) within the stent differed according to the device employed, the lowest SI being observed within the Palmaz stent (p = .001). There was no difference in SI or apparent diameter of the stent according to the sequence (SE vs GRE) or length of echo time (TE). In patients, the endoprostheses recorded as a well-defined area of signal void or drop-out (p = 0.004), whereas vessels above and below the stent displayed high signal intensities.
CONCLUSION: MRA does not seem as yet to be well suited for evaluating vascular patency after endoprosthesis placement, even if the Strecker and Wallstent endoprostheses provide fewer artifacts than the Palmaz stent.

Entities:  

Mesh:

Year:  1995        PMID: 8591621     DOI: 10.1007/bf00338302

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  20 in total

Review 1.  Current status of intravascular ultrasonography.

Authors:  B T Katzen
Journal:  Radiol Clin North Am       Date:  1992-09       Impact factor: 2.303

2.  Percutaneous iliac artery stent: angiographic long-term follow-up.

Authors:  A L Long; P E Page; A C Raynaud; B M Beyssen; J N Fiessinger; P Ducimetière; J Y Relland; J C Gaux
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

3.  Popliteal and tibioperoneal arteries: feasibility of two-dimensional time-of-flight MR angiography and phase velocity mapping.

Authors:  G R Caputo; T Masui; G A Gooding; J M Chang; C B Higgins
Journal:  Radiology       Date:  1992-02       Impact factor: 11.105

4.  Expandable tubular stents for treatment of arterial occlusive diseases: experimental and clinical results. Work in progress.

Authors:  E P Strecker; D Liermann; K H Barth; H R Wolf; N Freudenberg; G Berg; M Westphal; P Tsikuras; M Savin; B Schneider
Journal:  Radiology       Date:  1990-04       Impact factor: 11.105

5.  Evaluation of ferromagnetism and magnetic resonance imaging artifacts of the Strecker tantalum vascular stent.

Authors:  G P Teitelbaum; M Raney; M J Carvlin; A H Matsumoto; K H Barth
Journal:  Cardiovasc Intervent Radiol       Date:  1989 May-Jun       Impact factor: 2.740

6.  Magnetic susceptibility artifacts in gradient-recalled echo MR imaging.

Authors:  L F Czervionke; D L Daniels; F W Wehrli; L P Mark; L E Hendrix; J A Strandt; A L Williams; V M Haughton
Journal:  AJNR Am J Neuroradiol       Date:  1988 Nov-Dec       Impact factor: 3.825

7.  Tantalum vascular stents: in vivo evaluation with MR imaging.

Authors:  A H Matsumoto; G P Teitelbaum; K H Barth; M J Carvlin; M A Savin; E P Strecker
Journal:  Radiology       Date:  1989-03       Impact factor: 11.105

8.  Femoral MR angiography versus conventional angiography: preliminary results.

Authors:  S F Quinn; T A Demlow; R W Hallin; L R Eidemiller; J Szumowski
Journal:  Radiology       Date:  1993-10       Impact factor: 11.105

9.  Iliac and femoral artery stenoses and occlusions: treatment with intravascular stents.

Authors:  R W Günther; D Vorwerk; K Bohndorf; I Peters; A el-Din; B Messmer
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

Review 10.  MR angiography: present and future.

Authors:  R R Edelman
Journal:  AJR Am J Roentgenol       Date:  1993-07       Impact factor: 3.959

View more
  3 in total

1.  Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings.

Authors:  Martin Heuschmid; Benjamin Wiesinger; Gunnar Tepe; Oliver Luz; Andreas F Kopp; Claus D Claussen; Stephan H Duda
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

2.  Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils.

Authors:  A M Masaryk; R Frayne; O Unal; A H Rappe; C M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

3.  Follow-up study on in-stent thrombosis after carotid stenting using multidetector CT angiography.

Authors:  Hirotaka Watarai; Yasuhiko Kaku; Mikito Yamada; Jouji Kokuzawa; Toshiki Tanaka; Takashi Andoh; Toru Iwama
Journal:  Neuroradiology       Date:  2009-01-27       Impact factor: 2.804

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.