Literature DB >> 8588715

Variation in rat urinary aeroallergen levels explained by differences in site, task and exposure group.

M J Nieuwenhuijsen1, S Gordon, J M Harris, R D Tee, K M Venables, A J Newman Taylor.   

Abstract

We describe how much of the variation in rat urinary aeroallergen (RUA) levels may be explained by differences in site and exposure group in research establishments and we identify task categories associated with high RUA levels. In this population 73% of the variability in RUA levels could be explained by exposure group, site and their interaction term. Exposure group alone explained the majority of the variation (69%). The task category associated with the highest RUA level was cleaning out, followed by indirect contact with rats and handling rats. The task categories associated with the lowest levels were slide production, post mortem and experiments. These results may help choose appropriate exposure measures for epidemiological studies in research establishments in the future and may help reduce the incidence of laboratory animal allergy.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8588715     DOI: 10.1016/0003-4878(95)00042-9

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  5 in total

1.  Exposure assessment of high molecular weight sensitisers: contribution to occupational epidemiology and disease prevention.

Authors:  D Heederik; G Doekes; M J Nieuwenhuijsen
Journal:  Occup Environ Med       Date:  1999-11       Impact factor: 4.402

Review 2.  Identification of determinants of exposure: consequences for measurement and control strategies.

Authors:  A Burdorf
Journal:  Occup Environ Med       Date:  2005-05       Impact factor: 4.402

3.  Incidence of allergy and allergy symptoms among workers exposed to laboratory animals.

Authors:  L Elliott; D Heederik; S Marshall; D Peden; D Loomis
Journal:  Occup Environ Med       Date:  2005-11       Impact factor: 4.402

4.  Exposure of laboratory animal care workers to airborne mouse and rat allergens.

Authors:  Joshua T Glueck; Richard B Huneke; Hernando Perez; Igor Burstyn
Journal:  J Am Assoc Lab Anim Sci       Date:  2012       Impact factor: 1.232

5.  Predictors for Increased and Reduced Rat and Mouse Allergen Exposure in Laboratory Animal Facilities.

Authors:  Anne Straumfors; Wijnand Eduard; Knut Andresen; Ann Kristin Sjaastad
Journal:  Ann Work Expo Health       Date:  2018-10-15       Impact factor: 2.179

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.