Portal dose measurement in radiotherapy using an electronic portal imaging device (EPID).

B J Heijmen1, K L Pasma, M Kroonwijk, V G Althof, J C de Boer, A G Visser, H Huizenga.   

Abstract

Physical characteristics of a commercially available electronic portal imaging device (EPID), relevant to dosimetric applications in high-energy photon beams, have been investigated. The EPID basically consists of a fluorescent screen, mirrors and a CCD camera. Image acquisition for portal dose measurement has been performed with a special procedure, written in the command language that comes with the system. The observed day-to-day variation in local EPID responses, i.e. measured grey scale value (EPID signal) per unit of delivered portal dose, is 0.4% (1 SD); day-to-day variation in relative EPID responses (e.g. normalized to the on-axis response) are within 0.2% (1 SD). Measured grey scale values are linearly proportional to transmitted portal doses with a proportionality constant which is independent of the thickness of a flat, water-equivalent absorber in the beam, but which does significantly depend on the size of the applied x-ray beam. It is shown that the observed increased in EPID response with increasing field size is mainly due to contributions to the EPID signals from scattered light: visible photons produced by the x-ray beam in a point of the fluorescent screen not only generate a grey scale value in the corresponding point of the EPID image, but also lead (due to scatter from components of the EPID structure onto the CCD chip) to an increased grey scale value at all other points of the image. A point spread function, derived from measured data and describing the increase in EPID response at the beam axis due to off-axis irradiation of the fluorescent screen, has been successfully applied to connect portal doses with grey scale values measured with the EPID.

Entities:  

Mesh:

Year:  1995        PMID: 8587942     DOI: 10.1088/0031-9155/40/11/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Dose verifications by use of liquid ionization chamber of an electronic portal imaging device (EPID).

Authors:  Kunihiko Tateoka; Atsushi Oouchi; Kensei Nakata; Masato Hareyama
Journal:  Radiol Phys Technol       Date:  2008-06-07

2.  Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification.

Authors:  C Varatharaj; Eugenia Moretti; M Ravikumar; Maria Rosa Malisan; Sanjay S Supe; Renato Padovani
Journal:  J Med Phys       Date:  2010-10

3.  Intensity modulated radiotherapy: advantages, limitations and future developments.

Authors:  Ky Cheung
Journal:  Biomed Imaging Interv J       Date:  2006-01-01

4.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

5.  Feasibility of using two-dimensional array dosimeter for in vivo dose reconstruction via transit dosimetry.

Authors:  Heeteak Chung; Jonathan Li; Sanjiv Samant
Journal:  J Appl Clin Med Phys       Date:  2011-04-08       Impact factor: 2.102

6.  A new approach for the pixel map sensitivity (PMS) evaluation of an electronic portal imaging device (EPID).

Authors:  Alberto Boriano; Francesco Lucio; Elisa Calamia; Elvio Russi; Flavio Marchetto
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

7.  Intensity-modulated radiation therapy dose verification using fluence and portal imaging device.

Authors:  Iori Sumida; Hajime Yamaguchi; Indra J Das; Hisao Kizaki; Keiko Aboshi; Mari Tsujii; Yuji Yamada; Osamu Suzuki; Yuji Seo; Fumiaki Isohashi; Kazuhiko Ogawa
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  Noncoplanar verification: a feasibility study using Philips' Pinnacle3 treatment planning system.

Authors:  Indra Yohannes; Heru Prasetio; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

9.  The use of extended dose range film for dosimetric calibration of a scanning liquid-filled ionization chamber electronic portal imaging device.

Authors:  Mohammad Mohammadi; Eva Bezak; Paul Reich
Journal:  J Appl Clin Med Phys       Date:  2006-05-15       Impact factor: 2.102

10.  On flattening filter-free portal dosimetry.

Authors:  Eduardo Pardo; Juan Castro Novais; María Yolanda Molina López; Sheila Ruiz Maqueda
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.