Literature DB >> 8582058

3-Hydroxyisovalerylcarnitine in patients with deficiency of 3-methylcrotonyl CoA carboxylase.

W Röschinger1, D S Millington, D A Gage, Z H Huang, T Iwamoto, S Yano, S Packman, K Johnston, S A Berry, L Sweetman.   

Abstract

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8582058     DOI: 10.1016/0009-8981(95)06126-2

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


× No keyword cloud information.
  9 in total

1.  Quantitative measurement of plasma 3-hydroxyisovaleryl carnitine by LC-MS/MS as a novel biomarker of biotin status in humans.

Authors:  Thomas D Horvath; Shawna L Stratton; Anna Bogusiewicz; Lindsay Pack; Jeffery Moran; Donald M Mock
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

2.  Urinary excretion of 3-hydroxyisovaleric acid and 3-hydroxyisovaleryl carnitine increases in response to a leucine challenge in marginally biotin-deficient humans.

Authors:  Donald M Mock; Shawna L Stratton; Thomas D Horvath; Anna Bogusiewicz; Nell I Matthews; Cindy L Henrich; Amanda M Dawson; Horace J Spencer; Suzanne N Owen; Gunnar Boysen; Jeffery H Moran
Journal:  J Nutr       Date:  2011-09-14       Impact factor: 4.798

3.  Is L-Carnitine Supplementation Beneficial in 3-Methylcrotonyl-CoA Carboxylase Deficiency?

Authors:  Jákup Andreas Thomsen; Allan Meldgaard Lund; Jess Have Olesen; Magni Mohr; Jan Rasmussen
Journal:  JIMD Rep       Date:  2015-03-03

Review 4.  3-Methylglutaric acid in energy metabolism.

Authors:  Dylan E Jones; Leanne Perez; Robert O Ryan
Journal:  Clin Chim Acta       Date:  2019-11-12       Impact factor: 3.786

5.  Urinary excretion of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans.

Authors:  Shawna L Stratton; Thomas D Horvath; Anna Bogusiewicz; Nell I Matthews; Cindy L Henrich; Horace J Spencer; Jeffery H Moran; Donald M Mock
Journal:  J Nutr       Date:  2011-01-19       Impact factor: 4.798

6.  Plasma concentration of 3-hydroxyisovaleryl carnitine is an early and sensitive indicator of marginal biotin deficiency in humans.

Authors:  Shawna L Stratton; Thomas D Horvath; Anna Bogusiewicz; Nell I Matthews; Cindy L Henrich; Horace J Spencer; Jeffery H Moran; Donald M Mock
Journal:  Am J Clin Nutr       Date:  2010-10-13       Impact factor: 7.045

7.  Measurement of 3-hydroxyisovaleric acid in urine from marginally biotin-deficient humans by UPLC-MS/MS.

Authors:  Thomas D Horvath; Nell I Matthews; Shawna L Stratton; Donald M Mock; Gunnar Boysen
Journal:  Anal Bioanal Chem       Date:  2011-09-03       Impact factor: 4.142

8.  Evaluation of 3-methylcrotonyl-CoA carboxylase deficiency detected by tandem mass spectrometry newborn screening.

Authors:  D D Koeberl; D S Millington; W E Smith; S D Weavil; J Muenzer; S E McCandless; P S Kishnani; M T McDonald; S Chaing; A Boney; E Moore; D M Frazier
Journal:  J Inherit Metab Dis       Date:  2003       Impact factor: 4.982

9.  Quantitative measurement of urinary excretion of 3-hydroxyisovaleryl carnitine by LC-MS/MS as an indicator of biotin status in humans.

Authors:  Thomas D Horvath; Shawna L Stratton; Anna Bogusiewicz; Suzanne N Owen; Donald M Mock; Jeffery H Moran
Journal:  Anal Chem       Date:  2010-10-28       Impact factor: 6.986

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.