| Literature DB >> 21892638 |
Thomas D Horvath1, Nell I Matthews, Shawna L Stratton, Donald M Mock, Gunnar Boysen.
Abstract
Measurement of 3-hydroxyisovaleric acid (3HIA) in human urine has been shown to be a useful indicator of biotin status for a variety of clinical situations, including pregnancy. The work described herein presents a novel UPLC-MS/MS method for accurate and precise quantitation of urinary 3HIA. This method utilizes sample preparation prior to quantitation that has been simplified compared to the previous GC-MS method. To demonstrate the suitability of the UPLC-MS/MS method for human bio-monitoring, this method was used to measure 3-HIA in 64 human urine samples from eight healthy adults in whom marginal biotin deficiency had been induced experimentally by egg white feeding. 3HIA was detected in all specimens; the mean concentration [±standard deviation (SD)] was 80.6 ± 51 μM prior to inducing biotin deficiency. Mean excretion rate for 3HIA (expressed per mol urinary creatinine) before beginning the biotin-deficient diet was 8.5 ± 3.2 mmol 3HIA per mol creatinine and the mean increased threefold with deficiency. These specimens had been previously analyzed by GC-MS; the two data sets showed strong linear relationship with a correlation coefficient of 0.97. These results provide evidence that this method is suitable for bio-monitoring of biotin status in larger populations.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21892638 PMCID: PMC3628633 DOI: 10.1007/s00216-011-5356-x
Source DB: PubMed Journal: Anal Bioanal Chem ISSN: 1618-2642 Impact factor: 4.142