Literature DB >> 8572962

Seal-less centrifugal blood pump with magnetically suspended rotor: rot-a-flot.

N Mendler1, F Podechtl, G Feil, P Hiltmann, F Sebening.   

Abstract

Limitations of current centrifugal blood pumps are related to heat generation of bearings and leakage of seals, to dead water zones, and to poor efficiency. A new concept is proposed in this paper to ameliorate these problems based on a miniaturized magnetic drive, and a prototype is introduced. The pump rotor is suspended and driven by a radial permanent magnetic field that stabilizes the impeller in 4 of the 6 spatial degrees of freedom and allows it to be top-spun on a single blood-flushed pivot bearing with minimal load and friction. A shrouded impeller with an open center and 4 logarithmically curved channels is run inside a cone-and-plate-type housing with a spiral volute chamber. In vitro testing was performed comparing this design with the BioMedicus, St. Jude, and Sarns pumps. The prototype is demonstrated to have the smallest internal volume (35 ml), surface (190 qcm), and passage time (0.5 s at 4 L/min), as well as the highest hydraulic efficiency (up to 0.4) of all devices studied.

Entities:  

Mesh:

Year:  1995        PMID: 8572962     DOI: 10.1111/j.1525-1594.1995.tb02391.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  11 in total

Review 1.  Contemporary extracorporeal membrane oxygenation for adult respiratory failure: life support in the new era.

Authors:  Graeme MacLaren; Alain Combes; Robert H Bartlett
Journal:  Intensive Care Med       Date:  2011-12-07       Impact factor: 17.440

2.  Up to 151 days of continuous animal perfusion with trivial heparin infusion by the application of a long-term durable antithrombogenic coating to a combination of a seal-less centrifugal pump and a diffusion membrane oxygenator.

Authors:  Tomohiro Nishinaka; Eisuke Tatsumi; Nobumasa Katagiri; Hiroyuki Ohnishi; Toshihide Mizuno; Kyoko Shioya; Tomonori Tsukiya; Akihiko Homma; Susumu Kashiwabara; Hidenori Tanaka; Masaki Sato; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-12-20       Impact factor: 1.731

Review 3.  Physiology of the Assisted Circulation in Cardiogenic Shock: A State-of-the-Art Perspective.

Authors:  Julien Guihaire; Francois Haddad; Mita Hoppenfeld; Myriam Amsallem; Jeffrey W Christle; Clark Owyang; Khizer Shaikh; Joe L Hsu
Journal:  Can J Cardiol       Date:  2019-11-09       Impact factor: 5.223

4.  Efficacy of new pediatric extra-corporeal life support system (Endumo 2000) for postoperative management after Norwood operation.

Authors:  Takaya Hoashi; Koji Kagisaki; Takayuki Nishigaki; Kotaro Yoshida; Teruyuki Hayashi; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2014-08-15       Impact factor: 1.731

5.  Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult.

Authors:  Koichi Kashiwa; Takashi Nishimura; Aya Saito; Hitoshi Kubo; Aoi Fukaya; Hisayoshi Tamai; Tomoyuki Yambe; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2012-02-23       Impact factor: 1.731

6.  Development of Inspired Therapeutics Pediatric VAD: Benchtop Evaluation of Impeller Performance and Torques for MagLev Motor Design.

Authors:  Landon H Tompkins; Steven R Prina; Barry N Gellman; Gino F Morello; Thomas Roussel; Jonathan A Kopechek; Stuart J Williams; Priscilla C Petit; Mark S Slaughter; Steven C Koenig; Kurt A Dasse
Journal:  Cardiovasc Eng Technol       Date:  2021-09-13       Impact factor: 2.305

7.  Early clinical outcomes of new pediatric extracorporeal life support system (Endumo (2000) in neonates and infants.

Authors:  Takaya Hoashi; Koji Kagisaki; Kizuku Yamashita; Eisuke Tatsumi; Takayuki Nishigaki; Kotaro Yoshida; Teruyuki Hayashi; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2013-05-30       Impact factor: 1.731

8.  Extracorporeal membrane oxygenation circuitry.

Authors:  Laurance Lequier; Stephen B Horton; D Michael McMullan; Robert H Bartlett
Journal:  Pediatr Crit Care Med       Date:  2013-06       Impact factor: 3.624

9.  Clinical experience of more than 2 months usage of extracorporeal membrane oxygenation (Endumo(®)4000) without circuit exchange.

Authors:  Kunio Kusajima; Takaya Hoashi; Koji Kagisaki; Kotaro Yoshida; Takayuki Nishigaki; Teruyuki Hayashi; Hajime Ichikawa
Journal:  J Artif Organs       Date:  2013-12-31       Impact factor: 1.731

10.  Membrane Lung and Blood Pump Use During Prolonged Extracorporeal Membrane Oxygenation: Trends From 2002 to 2017.

Authors:  McKenzie M Hayes; Brian P Fallon; Ryan P Barbaro; Niki Manusko; Robert H Bartlett; John M Toomasian
Journal:  ASAIO J       Date:  2021-09-01       Impact factor: 3.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.