Literature DB >> 33528156

Membrane Lung and Blood Pump Use During Prolonged Extracorporeal Membrane Oxygenation: Trends From 2002 to 2017.

McKenzie M Hayes1, Brian P Fallon1, Ryan P Barbaro2,3, Niki Manusko4, Robert H Bartlett1, John M Toomasian1,5.   

Abstract

Extracorporeal life support (ECLS) has grown in its application since its first clinical description in the 1970s. The technology has been used to support a wide variety of mechanical support modalities and diseases, including respiratory failure, cardiorespiratory failure, and cardiac failure. Over many decades and safety and efficacy studies, followed by randomized clinical trials and thousands of clinical uses, ECLS is considered as an accepted treatment option for severe pulmonary and selected cardiovascular failure. Extracorporeal life support involves the use of support artificial organs, including a membrane lung and blood pump. Over time, changes in the technology and the management of ECLS support devices have evolved. This manuscript describes the use of membrane lungs and blood pumps used during ECLS support from 2002 to 2017 in over 65,000 patients reported to the Extracorporeal Life Support Organization Registry. Device longevity and complications associated with membrane lungs and blood pump are described and stratified by age group: neonates, pediatrics, and adults.
Copyright © ASAIO 2021.

Entities:  

Mesh:

Year:  2021        PMID: 33528156      PMCID: PMC8316490          DOI: 10.1097/MAT.0000000000001368

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   3.826


  43 in total

1.  Extracorporeal membrane oxygenation and conventional medical therapy in neonates with persistent pulmonary hypertension of the newborn: a prospective randomized study.

Authors:  P P O'Rourke; R K Crone; J P Vacanti; J H Ware; C W Lillehei; R B Parad; M F Epstein
Journal:  Pediatrics       Date:  1989-12       Impact factor: 7.124

2.  Improved outcomes from extracorporeal membrane oxygenation versus ventricular assist device temporary support of primary graft dysfunction in heart transplant.

Authors:  Koji Takeda; Boyangzi Li; Arthur R Garan; Veli K Topkara; Jiho Han; Paolo C Colombo; Maryjane A Farr; Yoshifumi Naka; Hiroo Takayama
Journal:  J Heart Lung Transplant       Date:  2016-12-23       Impact factor: 10.247

3.  Extracorporeal Membrane Oxygenation for Severe Acute Respiratory Distress Syndrome.

Authors:  Alain Combes; David Hajage; Gilles Capellier; Alexandre Demoule; Sylvain Lavoué; Christophe Guervilly; Daniel Da Silva; Lara Zafrani; Patrice Tirot; Benoit Veber; Eric Maury; Bruno Levy; Yves Cohen; Christian Richard; Pierre Kalfon; Lila Bouadma; Hossein Mehdaoui; Gaëtan Beduneau; Guillaume Lebreton; Laurent Brochard; Niall D Ferguson; Eddy Fan; Arthur S Slutsky; Daniel Brodie; Alain Mercat
Journal:  N Engl J Med       Date:  2018-05-24       Impact factor: 91.245

4.  First experience with the new portable extracorporeal membrane oxygenation system Cardiohelp for severe respiratory failure in adults.

Authors:  A Haneya; A Philipp; M Foltan; D Camboni; T Müeller; T Bein; C Schmid; M Lubnow
Journal:  Perfusion       Date:  2012-01-16       Impact factor: 1.972

5.  Extracorporeal membrane oxygenation as a bridge to lung transplant: midterm outcomes.

Authors:  Christian A Bermudez; Rodolfo V Rocha; Diana Zaldonis; Jay K Bhama; Maria M Crespo; Norihisa Shigemura; Joseph M Pilewski; Penny L Sappington; Arthur J Boujoukos; Yoshiya Toyoda
Journal:  Ann Thorac Surg       Date:  2011-08-26       Impact factor: 4.330

6.  Evaluation of plasma resistant hollow fiber membranes for artificial lungs.

Authors:  Heide J Eash; Heather M Jones; Brack G Hattler; William J Federspiel
Journal:  ASAIO J       Date:  2004 Sep-Oct       Impact factor: 2.872

7.  Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO.

Authors:  S Horton; C Thuys; M Bennett; S Augustin; M Rosenberg; C Brizard
Journal:  Perfusion       Date:  2004-01       Impact factor: 1.972

8.  Extracorporeal membrane oxygenator support for cardiopulmonary failure. Experience in 28 cases.

Authors:  R H Bartlett; A B Gazzaniga; S W Fong; M R Jefferies; H V Roohk; N Haiduc
Journal:  J Thorac Cardiovasc Surg       Date:  1977-03       Impact factor: 5.209

9.  Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): a multicentre randomised controlled trial.

Authors:  Giles J Peek; Miranda Mugford; Ravindranath Tiruvoipati; Andrew Wilson; Elizabeth Allen; Mariamma M Thalanany; Clare L Hibbert; Ann Truesdale; Felicity Clemens; Nicola Cooper; Richard K Firmin; Diana Elbourne
Journal:  Lancet       Date:  2009-09-15       Impact factor: 79.321

10.  Plasma leakage through microporous membranes. Role of phospholipids.

Authors:  J P Montoya; C J Shanley; S I Merz; R H Bartlett
Journal:  ASAIO J       Date:  1992 Jul-Sep       Impact factor: 2.872

View more
  1 in total

1.  A pumpless artificial lung without systemic anticoagulation: The Nitric Oxide Surface Anticoagulation system.

Authors:  Brian P Fallon; Orsolya Lautner-Csorba; Alex J Thompson; Gergely Lautner; Adrianna Kayden; Matthew D Johnson; Stephen L Harvey; Mark W Langley; Alvaro Rojas Peña; Robert H Bartlett; Ronald B Hirschl
Journal:  J Pediatr Surg       Date:  2021-09-20       Impact factor: 2.545

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.