Literature DB >> 8570056

Autoperfusion balloon catheter for treatment of vertebral artery stenosis.

K Sampei1, N Hashimoto, K Kazekawa, S Yoshimura.   

Abstract

Percutaneous transluminal angioplasty (PTA) of the vertebral artery was performed with an autoperfusion balloon catheter in five patients. There were no complications in the form of embolic episodes or neurological deficits due to brain ischaemia during inflation. In critical cases with insufficient collateral circulation during temporary occlusion, the use of an autoperfusion balloon catheter may expand the indications for PTA in patients with ischaemic cerebrovascular disease.

Entities:  

Mesh:

Year:  1995        PMID: 8570056     DOI: 10.1007/bf00593722

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  6 in total

1.  Transluminal intracoronary reperfusion catheter: a device to maintain coronary perfusion between failed coronary angioplasty and emergency coronary bypass surgery.

Authors:  T Hinohara; J B Simpson; H R Phillips; R S Stack
Journal:  J Am Coll Cardiol       Date:  1988-05       Impact factor: 24.094

2.  Transluminal angioplasty of the vertebral and basilar artery.

Authors:  R T Higashida; G B Hieshima; F Y Tsai; V V Halbach; D Norman; T H Newton
Journal:  AJNR Am J Neuroradiol       Date:  1987 Sep-Oct       Impact factor: 3.825

3.  Preservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.

Authors:  Z G Turi; C A Campbell; M V Gottimukkala; R A Kloner
Journal:  Circulation       Date:  1987-06       Impact factor: 29.690

4.  Percutaneous Transluminal Angioplasty in Non-Atheroscklerotic Disease.

Authors:  E C Martin; N G Diamond; W J Casarella
Journal:  Radiology       Date:  1980-04       Impact factor: 11.105

5.  Transluminal angioplasty for atherosclerotic disease of the vertebral and basilar arteries.

Authors:  R T Higashida; F Y Tsai; V V Halbach; C F Dowd; T Smith; K Fraser; G B Hieshima
Journal:  J Neurosurg       Date:  1993-02       Impact factor: 5.115

6.  Myocardial protection during coronary angioplasty with an autoperfusion balloon catheter in humans.

Authors:  P J Quigley; T Hinohara; H R Phillips; R H Peter; V S Behar; Y Kong; C A Simonton; J A Perez; R S Stack
Journal:  Circulation       Date:  1988-11       Impact factor: 29.690

  6 in total
  1 in total

Review 1.  Percutaneous transluminal angioplasty and stenting for vertebral artery stenosis.

Authors:  L J Coward; R L Featherstone; M M Brown
Journal:  Cochrane Database Syst Rev       Date:  2005-04-18
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.