Literature DB >> 2952374

Preservation of distal coronary perfusion during prolonged balloon inflation with an autoperfusion angioplasty catheter.

Z G Turi, C A Campbell, M V Gottimukkala, R A Kloner.   

Abstract

A newly designed balloon coronary angioplasty catheter that allows passive antegrade blood flow during balloon inflation (autoperfusion catheter) was compared with a standard balloon coronary angioplasty catheter. In a randomized sequence, inflations were performed for 3 min in the left circumflex coronary artery of 12 dogs with the standard catheter followed by the autoperfusion catheter or vice versa. During inflation with the standard catheter, the ST segment of standard limb lead II increased from -0.02 +/- 0.03 mV to 0.39 +/- 0.08 mV (p less than .001), whereas during inflation with the autoperfusion catheter the ST segment did not change (-0.03 +/- 0.03 vs -0.01 +/- 0.04 mV; p = NS). Regional myocardial blood flow measured by the radioactive microsphere technique in the posterior subepicardium and subendocardium was 0.12 +/- 0.03 and 0.08 +/- 0.03 ml/min/g, respectively, with the standard catheter as compared with 0.57 +/- 0.08 and 0.61 +/- 0.14 ml/min/g with the autoperfusion catheter (both p less than .01 compared with the standard catheter). Thus, unlike the standard catheter, the autoperfusion catheter allows for inflations up to 3 min in duration without producing deleterious changes in the ST segment or severe reductions in regional myocardial blood flow.

Entities:  

Mesh:

Year:  1987        PMID: 2952374     DOI: 10.1161/01.cir.75.6.1273

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Autoperfusion balloon catheter for treatment of vertebral artery stenosis.

Authors:  K Sampei; N Hashimoto; K Kazekawa; S Yoshimura
Journal:  Neuroradiology       Date:  1995-10       Impact factor: 2.804

Review 2.  Revascularization therapy for coronary artery disease. Coronary artery bypass grafting versus percutaneous transluminal coronary angioplasty.

Authors:  J M Wilson; J J Ferguson
Journal:  Tex Heart Inst J       Date:  1995

3.  Distal coronary hemoperfusion and prolonged balloon inflation for acute occlusion: occurring during percutaneous transluminal coronary angioplasty.

Authors:  J Heibig; S Harris
Journal:  Tex Heart Inst J       Date:  1990

4.  A randomized controlled clinical trial of prolonged balloon inflation during stent deployment strategy in primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: a pilot study.

Authors:  Min Ma; Ling Wang; Kai-Yue Diao; Shi-Chu Liang; Ye Zhu; Hua Wang; Mian Wang; Li Zhang; Zhi-Gang Yang; Yong He
Journal:  BMC Cardiovasc Disord       Date:  2022-02-04       Impact factor: 2.298

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.