Literature DB >> 8570043

Iodixanol in intra-arterial cerebral digital subtraction angiography: a comparison with iohexol.

B E Kendall1, A Sheppick, J O Nossen, J M Stevens.   

Abstract

We randomised 86 patients undergoing intra-arterial cerebral digital subtraction angiography (IADSA) to receive iodixanol (Visipaque; Nycomed, Oslo, Norway) 150 mgI/ml or iohexol (Omnipaque; Nycomed) 140 mgI/ml. The efficacy and safety of these two contrast media were compared: efficacy by evaluating the diagnostic information and radiographic density yielded by the angiograms, safety by recording all discomfort connected with the injections, and all adverse events up to 24 h after the investigation. Diagnostic information was optimal in all patients and the overall radiographic density optimal in all but one (iohexol) (P = 0.49). A feeling of warmth, the only discomfort reported, was experienced by 43% and 54% of patients receiving iodixanol and iohexol, respectively (P = 0.26). Two patients in the iodixanol group and five in the iohexol group reported one adverse event (nausea, dizziness, visual disturbance or paraesthesiae) (P = 0.30); all were of mild severity except for one moderate adverse event in each group. Iodixanol 150 mgI/ml and iohexol 140 mgI/ml were demonstrated to be suitable for IADSA, with no clinically or statistically significant differences in efficacy, discomfort or adverse events.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8570043     DOI: 10.1007/bf00593706

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  11 in total

1.  Safety and tolerability of iodixanol in healthy volunteers with reference to two monomeric X-ray contrast media.

Authors:  N P Jørgensen; J O Nossen; K W Borch; A B Kristiansen; D T Kristoffersen; B Lundby; L Theodorsen
Journal:  Eur J Radiol       Date:  1992-10       Impact factor: 3.528

2.  Safety and tolerability of iodixanol. A dimeric, nonionic contrast medium: an emphasis on European clinical phases I and II.

Authors:  B Bolstad; K W Borch; B H Grynne; B Lundby; J O Nossen; Y F Kloster; D T Kristoffersen; E Andrew
Journal:  Invest Radiol       Date:  1991-11       Impact factor: 6.016

3.  Criteria for choice and use of contrast media in intra-arterial D.S.A.

Authors:  L Dalla-Palma; F Stacul; R Pozzi-Mucelli
Journal:  Eur J Radiol       Date:  1985-02       Impact factor: 3.528

4.  Iodixanol in excretory urography: initial clinical experience with a nonionic, dimeric (ratio 6:1) contrast medium. Work in progress.

Authors:  M L Gavant; R L Siegle
Journal:  Radiology       Date:  1992-05       Impact factor: 11.105

5.  A double-blind study comparing safety, tolerability and efficacy of iodixanol 320 mgI/ml and ioxaglate 320 mgI/ml in cerebral arteriography.

Authors:  Y Palmers; D De Greef; B H Grynne; J Smits; E Put
Journal:  Eur J Radiol       Date:  1993-11       Impact factor: 3.528

6.  Iodixanol in femoral arteriography (phase III): a comparative double-blind parallel trial between iodixanol and iopromide.

Authors:  N D Pugh; G R Sissons; M S Ruttley; K J Berg; J O Nossen; H Eide
Journal:  Clin Radiol       Date:  1993-02       Impact factor: 2.350

7.  The effect of iodixanol, a new isotonic contrast agent, on femoral blood flow in man.

Authors:  N D Pugh; G R Sissons; M Ruttley
Journal:  Clin Radiol       Date:  1992-04       Impact factor: 2.350

8.  Sodium-calcium balance and cardiac function with isotonic iodixanol. An experimental study in the isolated rat heart.

Authors:  P Jynge; T Holten; A N Oksendal
Journal:  Invest Radiol       Date:  1993-01       Impact factor: 6.016

9.  Reducing the risk of ventricular fibrillation by adding sodium to ionic and non-ionic contrast media with low iodine concentration. Coronary perfusion of the isolated rabbit heart with meglumine diatrizoate or iopentol at 140 mg I/ml and 0-154 mmol Na+/l.

Authors:  L Bååth; T Almén
Journal:  Acta Radiol       Date:  1989 Mar-Apr       Impact factor: 1.990

10.  Iodixanol--a new nonionic dimer--in aortofemoral angiography.

Authors:  U Albrechtsson; H Lárusdóttir; L Norgren; B Lundby
Journal:  Acta Radiol       Date:  1992-11       Impact factor: 1.990

View more
  2 in total

1.  Patient discomfort associated with the use of intra-arterial iodinated contrast media: a meta-analysis of comparative randomized controlled trials.

Authors:  Peter A McCullough; Patrizio Capasso
Journal:  BMC Med Imaging       Date:  2011-05-24       Impact factor: 1.930

2.  Headaches during angiography and endovascular procedures.

Authors:  Raquel Gil-Gouveia; Rita Fernandes Sousa; Leonor Lopes; Jorge Campos; Isabel Pavão Martins
Journal:  J Neurol       Date:  2007-04-06       Impact factor: 4.849

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.