Literature DB >> 8564149

Development of a non-linear finite element modelling of the below-knee prosthetic socket interface.

M Zhang1, M Lord, A R Turner-Smith, V C Roberts.   

Abstract

A non-linear finite element model has been established to predict the pressure and shear stress distribution at the limb-socket interface in below-knee amputees with consideration of the skin-liner interface friction and slip. In this model, the limb tissue and socket liner were respectively meshed into 954 and 450 three-dimensional eight-node isoparametric brick elements, based on measurements of an individual's amputated limb surface; the bone was meshed into three-dimensional six-node triangular prism elements, based on radiographic measurements of the individual's residual limb. The socket shell was assumed to be a rigid boundary. An important feature of this model is the use of 450 interface elements (ABAQUS INTER4) which mimic the interface friction condition. The results indicate that a maximum pressure of 226 kPa, shear stress of 53 kPa and less than 4 mm slip exist at the skin-liner interface when the full body weight of 800 N is applied to the limb. The results also show that the coefficient of friction is a very sensitive parameter in determining the interface pressures, shear stresses and slip. With the growth of coefficient of friction, the shear stresses will increase, while the pressure and slip will decrease.

Mesh:

Year:  1995        PMID: 8564149     DOI: 10.1016/1350-4533(95)00002-5

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Development of Standardized Material Testing Protocols for Prosthetic Liners.

Authors:  John C Cagle; Per G Reinhall; Brian J Hafner; Joan E Sanders
Journal:  J Biomech Eng       Date:  2017-04-01       Impact factor: 2.097

2.  A finite element model to assess transtibial prosthetic sockets with elastomeric liners.

Authors:  John C Cagle; Per G Reinhall; Kate J Allyn; Jake McLean; Paul Hinrichs; Brian J Hafner; Joan E Sanders
Journal:  Med Biol Eng Comput       Date:  2017-12-13       Impact factor: 2.602

Review 3.  Review of the socket design and interface pressure measurement for transtibial prosthesis.

Authors:  Gh Pirouzi; N A Abu Osman; A Eshraghi; S Ali; H Gholizadeh; W A B Wan Abas
Journal:  ScientificWorldJournal       Date:  2014-08-13

4.  Analysis of Pressure Distribution in Transfemoral Prosthetic Socket for Prefabrication Evaluation via the Finite Element Method.

Authors:  Mohd Syahmi Jamaludin; Akihiko Hanafusa; Yamamoto Shinichirou; Yukio Agarie; Hiroshi Otsuka; Kengo Ohnishi
Journal:  Bioengineering (Basel)       Date:  2019-10-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.