Literature DB >> 8559691

The effectiveness of cut-proof glove liners: cut and puncture resistance, dexterity, and sensibility.

J A Salkin1, S A Stuchin, F J Kummer, R Reininger.   

Abstract

Five types of commercial glove liners (within double latex gloves) were compared to single and double latex gloves for cut and puncture resistance and for relative manual dexterity and degree of sensibility. An apparatus was constructed to test glove-pseudofinger constructs in either a cutting or puncture mode. Cutting forces, cutting speed, and type of blade (serrated or scalpel blade) were varied and the time to cut-through measured by an electrical conductivity circuit. Penetration forces were similarly determined with a scalpel blade and a suture needle using a spring scale loading apparatus. Dexterity was measured with an object placement task among a group of orthopedic surgeons. Sensibility was assessed with Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry using standard techniques and rating scales. A subjective evaluation was performed at the end of testing. Time to cut-through for the liners ranged from 2 to 30 seconds for a rapid oscillating scalpel and 4 to 40 seconds for a rapid oscillating serrated knife under minimal loads. When a 1 kg load was added, times to cut-through ranged from 0.4 to 1.0 second. In most cases, the liners were superior to double latex. On average, 100% more force was required to penetrate the liners with a scalpel and 50% more force was required to penetrate the liners with a suture needle compared to double latex. Object placement task times were not significantly liners compared to double latex gloves. Semmes-Weinstein monofilaments, two-point discrimination, and vibrametry showed no difference in sensibility among the various liners and double latex gloves. Subjects felt that the liners were minimally to moderately impairing. An acclimation period may be required for their effective use.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8559691     DOI: 10.3928/0147-7447-19951101-05

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  3 in total

Review 1.  Double gloving to reduce surgical cross-infection.

Authors:  J Tanner; H Parkinson
Journal:  Cochrane Database Syst Rev       Date:  2006-07-19

2.  Surgeon and human immunodeficiency virus infection.

Authors:  Fouzia Rasool; Reyaz A Lone; Iqbal Rasool; Shabir Shah; Mubashir Shah; Irfan Rasool; Wani Mohd Lateef; Ishtiyaq A Mir; Roohi Rasool; Altaf Rasool; Sajad Arif; Furquan Nizami
Journal:  Int J Health Sci (Qassim)       Date:  2009-07

3.  Workers' compensation claim counts and rates by injury event/exposure among state-insured private employers in Ohio, 2007-2017.

Authors:  Steven J Wurzelbacher; Alysha R Meyers; Michael P Lampl; P Timothy Bushnell; Stephen J Bertke; David C Robins; Chih-Yu Tseng; Steven J Naber
Journal:  J Safety Res       Date:  2021-09-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.